• Investigative radiology · Nov 2014

    Virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in head and neck cancer.

    • Julian L Wichmann, Eva-Maria Nöske, Johannes Kraft, Iris Burck, Jens Wagenblast, Anne Eckardt, Claudia Frellesen, J Matthias Kerl, Ralf W Bauer, Boris Bodelle, Thomas Lehnert, Thomas J Vogl, and Boris Schulz.
    • From the Departments of *Diagnostic and Interventional Radiology and †Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt, Germany.
    • Invest Radiol. 2014 Nov 1; 49 (11): 735-41.

    ObjectivesThe aim of this study was to evaluate the effects on objective and subjective image quality of virtual monoenergetic reconstructions at various energy levels of dual-energy computed tomography (DECT) in patients with head and neck cancer.Materials And MethodsWe included 71 (53 men, 18 women; age, 59.3 ± 12.0 years; range, 33-90 years) patients with biopsy-proven untreated primary (n = 55) or recurrent (n = 16) squamous cell carcinoma who underwent head and neck DECT. Images were reconstructed with a linear blending setting emulating 120 kV acquisition (M_0.3; 30% of 80 kV, 70% of 140 kV spectrum) and as virtual monoenergetic images with photon energies of 40, 60, 80, and 100 keV. Attenuation of lesion, various anatomic landmarks, and image noise were objectively measured, and lesion contrast-to-noise ratio (CNR) was calculated. Two independent blinded radiologists subjectively rated each image series using a 5-point grading scale regarding overall image quality, lesion delineation, image sharpness, and image noise.ResultsTumor attenuation peaked at 40 keV (140.2 ± 42.6 HU) followed by the 60 keV (121.7 ± 25.5 HU) and M_0.3 series (102.7 ± 22.3; all P < 0.001). However, the calculated lesion CNR was highest in the 60 keV reconstructions (12.45 ± 7.17), 80 keV reconstructions (8.66 ± 6.58), and M_0.3 series (5.21 ± 3.15; all P < 0.001) and superior to the other monoenergetic series (all P < 0.001). Subjective image analysis was highest for the 60 keV series regarding overall image quality (4.22; κ = 0.411) and lesion delineation (4.35; κ = 0.459) followed by the M_0.3 series (3.81; κ = 0.394; 3.77; κ = 0.451; all P < 0.001). Image sharpness showed no significant difference between both series (3.81 vs 3.79; P = 0.78). Image noise was rated superior in the 80 and 100 keV series (4.31 vs 4.34; P = 0.522).ConclusionsCompared with linearly blended images, virtual monoenergetic reconstructions of DECT data at 60 keV significantly improve lesion enhancement and CNR, subjective overall image quality, and tumor delineation of head and neck squamous cell carcinoma.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…