• Masui · Feb 1995

    Comparative Study

    [Measurements of ventilatory parameters during closed circuit anesthesia--comparisons with semiclosed circuit, high-flow anesthesia].

    • S Morita, H Saito, T Hayashi, T Goto, and Y Niimi.
    • Department of Anesthesia, Teikyo University Ichihara Hospital.
    • Masui. 1995 Feb 1; 44 (2): 210-5.

    AbstractSince induction of anesthesia using a closed-circuit technique is difficult with most modern anesthesia machines, it is a common clinical practice to convert semiclosed, high-flow anesthesia (SCA) to closed circuit anesthesia (CCA) during the maintenance phase by decreasing the fresh gas flow. The purpose of the current studies was to determine if such changes in the fresh gas flow influence parameters of ventilatory dynamics. The tidal volume, airway pressure, and a ratio of expiratory volume in one second to a tidal volume (EV1.0/VT) were measured in six patients and in a lung simulator during CCA with a fresh gas flow of 200 ml.min-1 and SCA with a flow of 6 l.min-1. The ventilator settings were constant throughout the experiments. Dynamic compliance was calculated as (measured VT)/(peak airway pressure-positive end-expiratory pressure). Both in patients and in a lung simulator, dynamic compliance and EV1.0/VT were higher during CCA as compared to SCA while the tidal volume and airway pressure were lower. It was also suggested that these differences were secondary to differences in the fresh gas flow and not to the circuit situation (closed vs. semiclosed) per se. The results emphasize that the fresh gas flow should be taken into consideration in interpreting the data of ventilatory dynamics during anesthesia. This is especially so during CCA because CCA employs a minimum fresh gas flow.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.