• J. Orthop. Res. · Jul 2017

    Comparative Study

    Biomechanical comparison of augmented versus non-augmented sacroiliac screws in a novel hemi-pelvis test model.

    • Niklas Grüneweller, Michael J Raschke, Ivan Zderic, Daniel Widmer, Dirk Wähnert, Boyko Gueorguiev, Richards Robert Geoff RG AO Research Institute Davos, Clavadelerstraße 8, 7270 Davos, Switzerland., Thomas Fuchs, and Markus Windolf.
    • AO Research Institute Davos, Clavadelerstraße 8, 7270 Davos, Switzerland.
    • J. Orthop. Res. 2017 Jul 1; 35 (7): 1485-1493.

    AbstractOperative treatment of sacral insufficiency fractures is frequently being complicated by osteopenic bone properties. Cement augmentation of implanted sacroiliac screws may lead to superior construct stability and prevent mechanical complications. A novel hemi-pelvis test model with dissected symphysis was developed. Five fresh-frozen cadaveric pelvises were vertically osteotomized at the sacrum on both sides and fixed with sacroiliac screws in both corridors of the first sacral vertebral body. One side was randomly augmented with bone cement. Cyclic testing consisting of torsional loading (±2.5 Nm) combined with progressively increasing axial loading (+50 N compression, -10 N traction, ±0,01 N/cycle) was performed until failure; simulated physiological loads derived from inverse dynamic calculations. The fixation was analyzed fluoroscopically quantifying screw migrations and assessing failure mechanisms. Failure modes were cut-out, pull-out, screw-out, and washer penetration. Motion at fracture site was analyzed via optical motion tracking. Unscrewing was provoked four times with non-augmented and twice with augmented screws. When focusing on the sacral region only, cement augmentation significantly improved screw fixation in terms of increased number of cycles to failure (p = 0.043). However, when considering overall construct stability, there was no significant difference between augmented and non-augmented state due to washer penetration at the iliac bone. The generated hemi-pelvis model was found to be valid due to the reproduction of the clinically observed failure mode (unscrewing). Unscrewing was not fully prevented by cement augmentation. Augmentation effects stability at the screw tip, but particularly in porotic bone, failure may shift to the next weak point. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1485-1493, 2017.© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…