Paediatric anaesthesia · Dec 2013
Comparative StudyWashout times of desflurane, sevoflurane and isoflurane from the GE healthcare Aisys(®) and Avance(®) Carestation(®) and Aestiva(®) Anesthesia System.
- Tae W Kim, Jamie R Wingate, Allison M Fernandez, Emmett Whitaker, and Robert Q Tham.
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins Hospital, Baltimore, MD, USA.
- Paediatr Anaesth. 2013 Dec 1; 23 (12): 1124-30.
Background/AimMalignant hyperthermia susceptible patients may experience a fatal reaction to volatile anesthetic gases. This study sought to determine the washout characteristics of desflurane, sevoflurane, and isoflurane from the Aisys® , Avance® , and Aestiva® anesthesia machines. (GE Healthcare, Madison, WI, USA).MethodsAll machines were inspected by a GE Healthcare engineer prior to testing. The machines were primed with desflurane 7 vol%, sevoflurane 2.5 vol%, and isoflurane 1.2 vol% on three separate occasions for 2 h each with each gas. The Aisys® and Avance® were tested with and without an Advanced Breathing System (ABS™ , GE Healthcare, Madison, WI, USA). The Aestiva® was tested without modification to its breathing system. Additionally, the Aisys was evaluated with desflurane 1.2 vol% and the Avance with a preflushed fresh gas line was tested with an autoclaved ABS. After priming, disposable components of the patient breathing system were replaced. The fresh gas flow was increased to 15 lpm. Gas measurements were recorded until the concentration was 4 parts per million (p.p.m).ResultsThe fastest median washout time was achieved by the Avance in 3 min or less without an ABS or with an autoclaved ABS. The longest median time was 35 min for the Aestiva® . Clearance of desflurane was the most time consuming for all machines.ConclusionThis study demonstrates that saturated vapor pressure and priming concentration exert a greater effect on washout times than gas solubility. The Aisys utilizes an electronic vaporizer system that may expose the breathing system to retained saturated vapor. The breathing systems for all machines may hinder washout of gases.© 2013 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.