-
Comparative Study Observational Study
Comparison of End-Tidal, Arterial, Venous, and Transcutaneous PCO2.
- Shota Fujimoto, Manabu Suzuki, Keita Sakamoto, Ritsu Ibusuki, Kentaro Tamura, Ayako Shiozawa, Satoru Ishii, Motoyasu Iikura, Shinyu Izumi, and Haruhito Sugiyama.
- Department of Respiratory Medicine, National Center for Global Health and Medicine, Tokyo, Japan.
- Respir Care. 2019 Oct 1; 64 (10): 1208-1214.
BackgroundWe investigated the measurement of end-tidal partial pressure of carbon dioxide (PETCO2 ) with a capnometer in patients with respiratory failure, and we determined whether this technique could provide an alternative to measurement of PaCO2 using arterial blood gas analysis in the clinical setting.MethodsWe measured PETCO2 in subjects with hypoxemic and hypercarbic respiratory failure using a capnometer. We simultaneously measured PaCO2 , venous partial pressure of carbon dioxide (Pv̄CO2 ), and transcutaneously measured partial pressure PCO2 (PtcCO2 ). We analyzed agreements among these parameters with Bland-Altman analysis. We obtained 30 samples from subjects with hypoxemic respiratory failure and 30 samples from subjects with hypercarbic respiratory failure.ResultsThirty subjects with hypoxemic respiratory failure and 18 subjects with hypercarbic respiratory failure participated in this study. Significant relationships were found between PETCO2 and PaCO2 , between PtcCO2 and PaCO2 , and between Pv̄CO2 and PaCO2 . Bland-Altman analysis of PETCO2 and PaCO2 in all subjects revealed a bias of 6.48 mm Hg (95% CI 4.93-8.03, P < .001) with a precision of 6.01 mm Hg. Bland-Altman analysis of PETCO2 and PaCO2 with hypoxemic respiratory failure revealed a bias of 5.14 mm Hg (95% CI 3.35-6.93, P < .001) with a precision of 4.80 mm Hg. Bland-Altman analysis of PETCO2 and PaCO2 in subjects with hypercarbic respiratory failure revealed a bias of 7.83 mm Hg (95% CI 5.27-10.38, P < .001) with a precision of 6.83 mm Hg.ConclusionsPETCO2 can be measured simply using a capnometer, and PETCO2 measurements can estimate PaCO2 . However, the limits of agreement were wide. Therefore, care providers must pay attention to the characteristics and errors of these devices. These results suggest that measurement of PETCO2 might be useful for screening for hypercarbic respiratory failure in the clinical setting.Copyright © 2019 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.