Comparative Study Observational Study
Diagnostic Accuracy and Time-Saving Effects of Point-of-Care Ultrasonography in Patients With Small Bowel Obstruction: A Prospective Study.
- Keith S Boniface, Jordan B King, Maxine A LeSaux, Stanislaw C Haciski, and Hamid Shokoohi.
- The George Washington University Medical Center, Washington, DC.
- Ann Emerg Med. 2020 Feb 1; 75 (2): 246-256.
Study ObjectiveWe evaluate the accuracy of point-of-care ultrasonography compared with computed tomographic (CT) scan and assess the potential time-saving effect of point-of-care ultrasonography in diagnosing small bowel obstruction.MethodsThis was a prospective observational study of a convenience sample of patients with suspected small bowel obstruction in an academic emergency department (ED). Physician sonographers were blinded to clinical data, laboratory results, and CT scan findings. Point-of-care ultrasonographic findings of small bowel obstruction was the primary outcome, defined as bowel-loop diameter greater than or equal to 25 mm with abnormal peristalsis. Maximum bowel dilatation, visible peristalsis, interluminal free fluid, and bowel wall thickness were evaluated. Time to completion of imaging results was abstracted from the medical records for each imaging modality.ResultsThe study included 125 patients (median age 54.0 years [interquartile range 43 to 63 years]; 46% men), of whom 32 (25.6%) had small bowel obstruction, and 9 (7.2%) underwent surgery for it. Overall, the sensitivity of point-of-care ultrasonography for small bowel obstruction was 87.5% (95% confidence interval 71.0% to 96.5%), and specificity was 75.3% (95% confidence interval 65.2% to 83.6%). The area under the receiver operating characteristic curve to accurately predict small bowel obstruction was 0.74 (95% confidence interval 0.66 to 0.82). Results were similar across evaluated subgroups, including physician training level. The average time to obtain a CT scan report was 3 hours, 42 minutes; obtaining an abdominal radiograph took 1 hour, 38 minutes; and the mean elapsed time to complete point-of-care ultrasonography was 11 minutes.ConclusionIn ED patients with suspected small bowel obstruction, point-of-care ultrasonography has a reasonably high accuracy in diagnosing small bowel obstruction compared with CT scan, and may substantially decrease the time to diagnosis.Copyright © 2019 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.