• J. Cardiothorac. Vasc. Anesth. · Dec 2018

    Reliability of Cardiac Output Measurements Using LiDCOrapid and Calibration by Transesophageal Echocardiography With the Continuous Pulmonary Artery Thermodilution Method in Patients Undergoing Aortic Valve Replacement for Aortic Stenosis.

    • Makoto Sato and Takayuki Kunisawa.
    • Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, 2-1-1-1 Midorigaoka Higashi, Asahikawa, Hokkaido 788-510, Japan. Electronic address: satomako@asahikawa-med.ac.jp.
    • J. Cardiothorac. Vasc. Anesth. 2018 Dec 1; 32 (6): 2495-2502.

    ObjectiveThis study investigated the accuracy of arterial waveform analysis estimations of cardiac output (COAW) and the efficacy of calibrations involving transesophageal echocardiography with continuous cardiac output values obtained using a pulmonary artery catheter.DesignProspective cohort study.SettingUniversity hospital operating room.ParticipantsTwelve patients undergoing aortic valve replacement for aortic stenosis.InterventionsA pulmonary artery catheter was placed in each patient, and continuous cardiac output was determined using thermodilution principles. LiDCOrapid and transesophageal echocardiography were used to measure COAW and to perform the calibration, respectively.Measurements And Main ResultsSimultaneous recording of continuous cardiac output and COAW values were performed every 20 minutes, after inducing anesthesia. COAW was calibrated using transesophageal echocardiography (COAW-cal) before and after initiating cardiopulmonary bypass (CPB); the COAW and COAW-cal were recorded concurrently using a LiDCOrapid monitor. For the pre-CPB dataset (34 data pairs), the mean bias and percentage error were, respectively, 0.10 L/min and 34% for COAW versus continuous cardiac output and -0.098 L/min and 27% for COAW-cal versus continuous cardiac output. Similarly, for the post-CPB (45 data pairs), the mean bias and percentage error were, respectively, 0.75 L/min and 34% for COAW and 0.059 L/min and 26% for COAW-cal. A 4-quadrant plot demonstrated an acceptable pre-CPB concordance rate of 93.3% for COAW and 93.8% for COAW-cal.ConclusionCOAW measurements, using LiDCOrapid, have acceptable trending ability pre-CPB. The determination of cardiac output variations, using transesophageal echocardiography, is useful for managing patients undergoing aortic valve replacement for aortic stenosis.Copyright © 2018. Published by Elsevier Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.