J. Cardiothorac. Vasc. Anesth. · Dec 2018
Impact of Obesity on Noninvasive Cardiac Hemodynamic Measurement by Electrical Cardiometry in Adults With Aortic Stenosis.
- Patrick Teefy, Rodrigo Bagur, Chantal Phillips, Kourosh Karimi-Shahri, John Teefy, Raksha Sule, Adam A Dempsey, and Kambiz Norozi.
- Department of Paediatrics, Division of Paediatric Cardiology, Western University, London, Canada.
- J. Cardiothorac. Vasc. Anesth. 2018 Dec 1; 32 (6): 2505-2511.
ObjectivesThere are substantial potential benefits to noninvasive cardiac monitoring methods, such as electrical cardiometry (EC), over more invasive methods, including significantly reduced risk of complications, lower up-front and operational costs, ease of use, and continuous monitoring. To take advantage of these technologies, clinical equivalence to currently established methods must be determined. The authors sought to determine if the noninvasive measurement of cardiac index (CI) by EC was clinically equivalent to thermodilution (TD) in adult patients with aortic stenosis (AS).DesignThis is a cross-sectional study comparing measurement devices in a single patient group.SettingSingle-center, university teaching hospital.ParticipantsThe study included 52 adult patients with aortic stenosis undergoing right heart catheterization.InterventionsCardiac output (CO) was measured concurrently using EC with an ICON device and TD in 52 participants with AS. CI values were to determine the accuracy and precision of EC in reference to TD. Percentage error (PE) was used to assess their clinical equivalence. The participants were divided further into groups (normal and overweight/obese) based on body mass index and the analysis was repeated.Measurements And Main ResultsCO measurement made by EC in adult patients with obesity or overweight was reduced significantly relative to TD. This was not observed in normal-weight adult AS patients. EC provided clinically equivalent measurements to TD for measuring CI in normal-weight adult AS patients (PE = 25.0%), but not for those adult AS patients with overweight or obesity (PE = 42.3%).ConclusionOverall, the ICON device produced lower CO and index measurements relative to TD in adult patients with AS. Overweight and obesity also significantly affected the relative precision and accuracy of the ICON electrical cardiometric device to measure CI in these patients.Copyright © 2018 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.