-
Comparative Study
Discrepancy between internal and external intracranial pressure transducers: quantification of an old source of error in EVDs?
- David Darrow, Alex Lee-Norris, Anthony Larson, Uzma Samadani, and Theoden I Netoff.
- Department of Neurosurgery, University of Minnesota, Minneapolis, Minnesota, USA. Electronic address: darro015@umn.edu.
- World Neurosurg. 2020 Jan 1; 133: e18-e25.
BackgroundIntracranial pressure monitoring remains the foundation for prevention of secondary injury after traumatic brain injury and is most commonly performed using an external ventricular drain or intraparenchymal pressure monitor. The Integra Flex ventricular catheter combines an external ventricular catheter with a pressure transducer embedded in the tip of the catheter to allow continuous pressure readings while simultaneously draining cerebrospinal fluid. Discrepancies between measurements from the continuously reported internal pressure transducer and intermittently assessed and externally transduced ventricular drain prompted an analysis and characterization of pressures transduced from the same ventricular source.MethodsMore than 500 hours of high-resolution (125 Hz) continuous recordings were manually reviewed to identify 73 hours of simultaneous measurements (clamped external ventricular drain) from internal and external transducers in patients with traumatic brain injury.ResultsA significant positive bias was found in pressure readings obtained from external relative to internal measurements. The 2 methods of measurement generally correlated poorly with each other and variably. Although proportional bias was found with Bland-Altman analysis, coherence revealed rare shifts in the external transducer as a major source of discrepancy. Infrequent changes in the 0-level of the external transducer were found to be the primary source of discrepancy. Relative to the observed differences, no significant trend was observed over time between the 2 modalities.ConclusionsThis study suggests that the internal pressure transducer may be a more reliable estimate of intracranial pressure relative to bedside external transducers due to the inherent behavioral requirement of leveling.Copyright © 2019 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.