    A comparison between sphygmomanometer-based and ambulatory blood pressure monitoring in acute salt loading and depletion protocol.

    • Carlos Eduardo Paiva, Andréia Fernanda Carvalho Leone Aguiar, Fernando Nobre, and Eduardo Barbosa Coelho.
    • Departamento de Clínica Medica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Brazil.
    • Clinics (Sao Paulo). 2011 Jan 1; 66 (5): 767-72.

    IntroductionAmbulatory blood pressure monitors have been used in salt loading and depletion protocols. However, the agreement between measurements made using ambulatory blood pressure monitors and those made with the sphygmomanometer has not been evaluated.ObjectiveThe objective of this study was to compare the concordance of the two methods of blood pressure measurements in protocols of acute salt loading and depletion.MethodSystolic blood pressure was measured using a sphygmomanometer at the completion of salt infusion (2 L NaCl 0.9%, 4 h) and salt depletion (furosemide, 120 mg/day, p.o.) in 18 volunteers. Using the Pearson correlation coefficient (ρ), these readings were compared with the mean systolic blood pressure measured using the ambulatory blood pressure monitoring device during the following periods: 4 h of saline infusion and 12 h of salt depletion; 4 h of saline infusion and the last 6 h of salt depletion; 12 h of salt loading and the last 6 h of depletion; 12 h of salt loading and 12 h of depletion. Salt sensitivity was defined by a difference in the systolic blood pressure between salt loading and salt depletion greater than 10 mmHg when measured with the sphygmomanometer, and the Kappa analysis of concordance (K) was used with a significance level of P<0.05.ResultsOnly the blood pressure readings obtained using the ambulatory blood pressure device during 4 h of intravenous NaCl and during 12 h of salt depletion showed a high correlation with the variation in the systolic blood pressure measured by the sphygmomanometer, with a full agreement with the salt sensitivity classification (p = 0.71; P = 0.001 and K=1).ConclusionIn acute salt loading and depletion protocols, an ambulatory blood pressure monitoring device should be used to record the blood pressure during the 4-h interval of salt infusion and 12-h interval of salt depletion.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…