Airway management with the Laryngeal Tube Suction II in a patient with cervical spine injury.
- Harald V Genzwuerker, C Tsagogiorgas, J Hinkelbein, and G Beck.
- Institute of Anaesthesiology and Intensive Care Medicine, University Hospital Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. harald.genzwuerker@anaes.ma.uni-heidelberg.de
- Resuscitation. 2005 May 1; 65 (2): 231-3.
AbstractSupraglottic airway devices may offer alternative strategies for securing the airway in patients with cervical spine injuries. A case of airway management with the LTS II, a modified version of the laryngeal tube suction, in a patient with a paramedian atlas fracture scheduled for decompression of a haematoma on the forehead is described. Device insertion was successful in the first attempt and a gastric tube was inserted without problems. Ventilation was uneventful, no complaints were stated after surgery.