• Am. J. Dis. Child. · Sep 1992

    Randomized Controlled Trial Clinical Trial

    Removing meconium from infant tracheae. What works best?

    • R C Bent, T E Wiswell, and A Chang.
    • Uniformed Services University of the Sciences, Bethesda, Md.
    • Am. J. Dis. Child. 1992 Sep 1; 146 (9): 1085-9.

    ObjectiveAt least nine mechanical devices are available for suctioning the tracheae of meconium-stained newborns. To our knowledge, the efficacy of these devices, as well as various suction pressures and patterns, has not been previously compared. We performed this investigation to assess these variables.DesignFourteen suction techniques (combinations of device, suction pressure, and suction intermittency) were evaluated sequentially in the trachea of each of 14 in vitro newborn piglets (1 to 4 days old); the order was randomized using a Latin square design. We chose three devices to compare: a meconium aspirator (Neotech Products Inc, Chatsworth, Calif), a hand pump (Res-Q-Vac, Repromed Systems Inc, New York, NY), and a 10F suction catheter (Superior Healthcare Group Inc, Cumberland, RI). Both the meconium aspirator and the hand pump were used with a 3.0-mm endotracheal tube.InterventionWe instilled 0.8 mL of a homogeneous mixture of human meconium and saline (44 g of meconium per 100 mL of saline) in the trachea before applying each suction technique. The meconium aspirator and the suction catheter were each evaluated at three different vacuum pressures, -40, -80, and -150 mm Hg, using both continuous and interrupted suction. The hand pump was evaluated with one and two activations (one activation generates -100 cm H2O, according to the manufacturer).Measurements And ResultsThe percentage of instilled meconium recovered was consistently greatest (P less than .001) with the meconium aspirator (mean, 88.9% at -150 mm Hg, 84.9% at -80 mm Hg, and 73.5% at -40 mm Hg), intermediate with the catheter (mean, 81.0% at -150 mm Hg, 73.2% at -80 mm Hg, and 67.5% at -40 mm Hg), and least for the hand pump (mean, 67.9% with one activation and 72.6% with two activations). Recovery was better with continuous suction (P = .02) and increasing pressure (P less than .001).ConclusionsAmong the techniques compared, the meconium aspirator at -150 mm Hg, using continuous suction, performed best in this model. It is unknown, however, to what extent the tracheal mucosa may be affected by this degree of negative pressure.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…