• Veterinary surgery : VS · Sep 2002

    Comparative Study

    A comparison of ultra-high-molecular weight polyethylene cable and stainless steel wire using two fixation techniques for repair of equine midbody sesamoid fractures: an in vitro biomechanical study.

    • Paul G Rothaug, Ray C Boston, Dean W Richardson, and David M Nunamaker.
    • Richard S. Reynolds, Jr, Comparative Orthopedic Research Laboratory, New Bolton Center, Department of Clinical Studies, College of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, USA.
    • Vet Surg. 2002 Sep 1; 31 (5): 445-54.

    ObjectiveTo compare the monotonic tensile and fatigue strength of 16-gauge stainless steel wire (SSW) to ultra-high-molecular weight polyethylene (UHMWPE) cable using a transfixed cerclage technique in an in vitro midbody sesamoid osteotomy model. Endoscopic modifications to Martins transfixed cerclage technique were developed. A new suture technique of fixation was compared with the transfixed cerclage technique by measuring gap formation after cyclic testing.Study DesignAn in vitro biomechanical paired equine cadaver limb study.Sample PopulationTwenty-one paired cadaveric adult equine forelimbs.MethodsUniaxial medial midbody sesamoid osteotomies were created in paired adult equine forelimbs. Monotonic tensile strength was measured on 10 forelimbs repaired by a transfixed cerclage technique using wire or cable. Fatigue testing to failure was performed on 4 forelimbs repaired using the transfixed cerclage technique by cycling the limbs between 500 N and 2,000 N. The limbs were initially repaired with wire, cycled until the wire broke, then repaired with cable and cycled again to failure. Fatigue testing for gap displacement was performed on 8 limbs repaired with either the transfixed cerclage technique or the suture technique. Limbs were cycled between 500 N and 2,000 N for 10,000 cycles. The limbs were repaired with wire initially, tested, and then repaired with cable and tested again. Twenty-two limbs were used for mechanical testing. The remaining limbs (20) were used to develop and practice the endoscopic transfixed cerclage (10 limbs) and suture (10 limbs) techniques.ResultsUltimate tensile strength (UTS) of UHMWPE cable constructs was 34% greater than the UTS of SSW constructs. Fatigue strength was 2 to 20 times greater for UHMWPE cable constructs than SSW constructs. Separation of fragments was 153% less for limbs repaired by the suture technique compared with those repaired by the transfixed cerclage technique.ConclusionsUHMWPE cable shows promise for this clinical application because of its greater tensile and fatigue strength. The newly described suture technique significantly reduced gap formation compared with the transfixed cerclage technique. Osteotomy gap formation occurred early in cycling, suggesting that rigid support in the form of a cast may be needed during the early postoperative period for wiring techniques.Clinical RelevanceClinical testing of UHMWPE cable should eliminate problems of wire breakage seen with SSW. The endoscopic transfixed cerclage technique can be used by surgeons familiar with arthroscopic surgery. However, the suture technique needs to be tested in vivo to determine whether there is a clinical advantage compared with the transfixed cerclage technique.Copyright 2002 by The American College of Veterinary Surgeons

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.