• Hand (New York, N.Y.) · Sep 2015

    Fixation for metacarpal neck fracture: a biomechanical study.

    • Pramote Malasitt, John R Owen, Marc-Antoine Tremblay, Jennifer S Wayne, and Jonathan E Isaacs.
    • Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, P.O. Box 980153, Richmond, VA 23298-0153 USA.
    • Hand (N Y). 2015 Sep 1; 10 (3): 438-43.

    BackgroundThere is no robust evidence of the best operative treatment for displaced unstable metacarpal neck fractures. Numerous constructs are used in the fixation of metacarpal neck fractures. Currently, two common methods are dorsal locking plate and K-wire fixation. A new metacarpal sled fixation system for metacarpal neck fracture was designed to provide fracture stability but limit dissection and avoid exposed hardware. The purpose of this study was to compare the biomechanical integrity of the metacarpal sled versus standard locking plate fixation and retrograde K-wire fixation in a simulated porcine metacarpal fracture model.MethodsTransverse metacarpal neck fractures were created in 30 porcine second metacarpals. The specimens were randomly fixed with locking plates, metacarpal sleds, or retrograde K-wires. Constructs were then loaded to failure in three-point bending. Stiffness and peak load were measured from the load-to-failure deflection curve. Data were analyzed via ANOVA, followed by Tukey-Kramer's post hoc pairwise comparison.ResultsThe K-wire group had the highest initial stiffness followed by the sled group and then the plate group. Statistical difference was only found between K-wires and plate. Peak load for the K-wire group was lowest, followed by sled, and then by plate. A statistically significant difference was observed between the peak loads of the K-wires and plate, as well as the sled and plate. However, a difference in peak load was not detected between the K-wires and sled.ConclusionsFor transverse metacarpal neck fractures, a metacarpal sled construct provides similar fixation to K-wires with limited dissection and without exposed hardware or the potential for soft tissue tethering. The new low profile construct using a minimally invasive technique would be suitable for unstable metacarpal neck fractures.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…