Paediatric anaesthesia · Sep 2019
Lung separation in children: Options and impact on gas exchange and lung compliance.
- Jason E Hale, Marcie R Meador, and Emad B Mossad.
- Anesthesiology Institute, Cleveland Clinic Foundation, Cleveland, OH, USA.
- Paediatr Anaesth. 2019 Sep 1; 29 (9): 915-919.
BackgroundOne-lung ventilation is a challenging airway technique in the pediatric population. Multiple airway devices can be employed, but there is no consensus as to the most reliable and physiologically advantageous method. This report is a review of the methods of one-lung ventilation in children in our practice, as well as an analysis of the impact of airway device type, patient age, and duration of lung separation on respiratory mechanics and gas exchange.MethodsThe records of all pediatric patients undergoing procedures requiring one-lung ventilation in a single center over an 18-month period were reviewed. Demographics, time required to achieve lung separation (anesthesia ready-time), and duration of one-lung ventilation were collected. Data from arterial blood gas analysis and ventilator parameters were collected at three time points: 15 minutes prior to one-lung ventilation (pre-OLV), 15 minutes after initiation of one-lung ventilation (during OLV), and 15 minutes after one-lung ventilation was ended (post-OLV). Standard equations for calculating compliance, the ratio of arterial partial pressure of oxygen to the fraction of inspired oxygen, and the alveolar-arterial oxygen gradient were used.ResultsForty-six patients were identified with a mean age of 9.3 (inner quartile range 3-15) years. All patients had significant changes in pulmonary function when comparing pre-OLV with during OLV and when comparing during OLV with post-OLV. There were no significant changes from pre- to post-OLV. On further analysis, there were more pronounced changes in compliance and gas exchange in older patients (P = 0.003; 95% CI: -0.62 to -0.14). There was also a significant decrease in post-OLV compliance with a longer duration of OLV (P = 0.018; 95% CI: -0.02 to <-0.01). Airway device type did not have significant impact on the parameters examined.ConclusionOur report demonstrates significant changes in lung function during one-lung ventilation. One particular device does not seem to be superior. Though pre-OLV measures of pulmonary function correlate closely with post-OLV, older age and a prolonged duration of one-lung ventilation did impact compliance.© 2019 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.