-
Paediatric anaesthesia · Sep 2019
A dedicated respiratory function monitor to improve tidal volume delivery during neonatal anesthesia.
- William K Atkins, Rob McDougall, Elizabeth J Perkins, Prue M Pereira-Fantini, and David G Tingay.
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Vic., Australia.
- Paediatr Anaesth. 2019 Sep 1; 29 (9): 920-926.
BackgroundTight control of tidal volume using accurate monitoring may improve neonatal outcomes. However, respiratory function monitors incorporated in current anesthetic workstations are generally inaccurate at tidal volumes used for infants.AimsTo determine if a specific respiratory function monitor for neonatal infants improved expired tidal volume delivery during anesthesia.MethodInfants <3 months old requiring intubation for surgery in the operating theater were studied. After intubation a Phillips NM3, Acutronic Florian, or Novametrix Ventcheck Respiratory Function Monitor was integrated into the circuit, and clinicians given access to the display for the duration of anesthesia. Breath-to-breath expired tidal volume delivery, leak, and delivered pressure were recorded, with cardiorespiratory parameters. These were compared with a matched control group with clinicians blinded to respiratory function monitor display.ResultsA total of 10 055 and 2569 inflations were measured in the respiratory function monitor visible (n = 32) and masked (n = 33) groups, respectively, with mean (standard deviation) delivered expired tidal volume 7.5 (2.4) mL/kg and 7.7 (3.0) mL/kg, respectively; mean difference (95% confidence interval) -0.2 (-1.1, 0.8) mL/kg (Welch's t test). In the visible group, 55.6% of expired tidal volumes were between 4 and 8 mL/kg compared to 51.7% in the masked group; relative benefit (95% confidence interval), 1.08 (1.03, 1.12). Expired tidal volume was less likely to be <4 mL/kg in the visible group compared to masked group; 6.4% vs 9.8%, 1.53 (1.33, 1.76). The use of a respiratory function monitor also reduced the number of inflations >10 mL/kg; 13.0% vs 22.0%, 1.11 (1.09, 1.14).ConclusionTidal volumes <4 mL/kg and >10 mL/kg are frequently delivered during neonatal anesthesia. The inclusion of an accurate respiratory function monitor may reduce the risk of exposure to potentially harmful tidal volumes.© 2019 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.