    Evaluation of Disposable and Traditional Accessory Devices for Use With a Pressurized Metered-Dose Inhaler.

    • Haitham Saeed, Mohamed Ea Abdelrahim, Hoda Rabea, and Heba F Salem.
    • Clinical Pharmacy Department, Faculty of Pharmacy, Beni-suef University, Beni-suef, Egypt.
    • Respir Care. 2020 Mar 1; 65 (3): 320-325.

    BackgroundThe use of accessory devices with pressurized metered-dose inhalers (pMDIs) enhances aerosol delivery and helps overcome any lack of patient coordination when using the pMDI. The use of accessory devices could be influenced by the efficacy, availability, and cost of these devices. The aim of this study was to compare drug delivery with the pMDI alone and with non-antistatic and antistatic accessory devices.MethodsThe total emitted dose and aerodynamic characterization of salbutamol particles were measured for the pMDI alone and for the pMDI combined with 4 different accessory devices: a homemade spacer, the Dolphin spacer, the DispozABLE paper spacer, and the AeroChamber Plus valved holding chamber. Aerodynamic characterization was analyzed with an Andersen cascade impactor at an inhalation flow of 28.3 L/min, and drug deposition was measured with high-performance liquid chromatography.ResultsThe mean ± SD total emitted dose from the pMDI alone, 155.2 ± 20.5 μg, was the greatest of all modalities, and the difference was significant (P < .001). The homemade and Dolphin spacers had the highest mean ± SD deposited amounts of salbutamol remaining on their walls (ie, 124.1 ± 11.1 μg and 131.5 ± 11.8 μg, respectively). The mean ± SD total emitted doses with the AeroChamber Plus valved holding chamber (61.9 ± 8.9 μg) and the DispozABLE paper spacer (76.4 ± 8.6 μg) were significantly higher than the emitted doses with the other devices. The mean ± SD fine-particle doses emitted with the AeroChamber plus valved holding chamber (51.4 ± 4.7 μg) and the DispozABLE paper spacer (39.7 ± 5.6 μg) were significantly higher than those with the other devices. The AeroChamber Plus valved holding chamber had the lowest mass median aerodynamic diameter (MMAD) values, but there were no statistically significant differences in MMAD between any of the combinations of pMDI and accessory device.ConclusionsThe valved holding chamber and the paper spacer had better aerodynamic characteristics than the other devices tested. We consider the antistatic devices to be the optimum devices for aerosol delivery due to their high efficacy compared to non-antistatic devices.Copyright © 2020 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…