• BMC anesthesiology · Jan 2017

    Comparative Study Clinical Trial

    Detection of critical cerebral desaturation thresholds by three regional oximeters during hypoxia: a pilot study in healthy volunteers.

    • Kerry L Tomlin, Anna-Maria Neitenbach, and Ulf Borg.
    • Department of Medical Affairs, Patient Monitoring & Recovery, Medtronic, 6135 Gunbarrel Ave, Boulder, CO, 80301, USA.
    • BMC Anesthesiol. 2017 Jan 13; 17 (1): 6.

    BackgroundRegional oximetry is increasingly used to monitor post-extraction oxygen status of the brain during surgical procedures where hemodynamic fluctuations are expected. Particularly in cardiac surgery, clinicians employ an interventional algorithm to restore baseline regional oxygen saturation (rSO2) when a patient reaches a critical desaturation threshold. Evidence suggests that monitoring cardiac surgery patients and intervening to maintain rSO2 can improve postoperative outcomes; however, evidence generated with one manufacturer's device may not be applicable to others. We hypothesized that regional oximeters from different manufacturers respond uniquely to changes in oxygen saturation in healthy volunteers.MethodsThree devices were tested: INVOS™ 5100C (Medtronic), EQUANOX™ 7600 (Nonin), and FORE-SIGHT™ (CASMED) monitors. We divided ten healthy subjects into two cohorts wearing a single sensor each from INVOS and EQUANOX (n = 6), or INVOS and FORE-SIGHT (n = 4). We induced and reversed hypoxia by adjusting the fraction of inspired oxygen. We calculated the magnitude of absolute rSO2 change and rate of rSO2 change during desaturation and resaturation, and determined if and when each device reached a critical interventional rSO2 threshold during hypoxia.ResultsAll devices responded to changes in oxygen directionally as expected. The median absolute rSO2 change and the rate of rSO2 change was significantly greater during desaturation and resaturation for INVOS compared with EQUANOX (P = 0.04). A similar but nonsignificant trend was observed for INVOS compared with FORE-SIGHT; our study was underpowered to definitively conclude there was no difference. A 10% relative decrease in rSO2 during desaturation was detected by all three devices across the ten subjects. INVOS met a 20% relative decrease threshold in all subjects of both cohorts, compared to 1 with EQUANOX and 2 with FORE-SIGHT. Neither EQUANOX nor FORE-SIGHT reached a 50% absolute rSO2 threshold compared with 4 and 3 subjects in each cohort with INVOS, respectively.ConclusionsSignificant differences exist between the devices in how they respond to changes in oxygen saturation in healthy volunteers. We suggest caution when applying evidence generated with one manufacturer's device to all devices.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.