Review
Should we titrate ventilation based on driving pressure? Maybe not in the way we would expect.
- Paolo Pelosi and Lorenzo Ball.
- Dipartimento di Scienze Chirurgiche e Diagnostiche Integrate, Università degli Studi di Genova, Genova, Italy.
- Ann Transl Med. 2018 Oct 1; 6 (19): 389.
AbstractMechanical ventilation maintains adequate gas exchange in patients during general anaesthesia, as well as in critically ill patients without and with acute respiratory distress syndrome (ARDS). Optimization of mechanical ventilation is important to minimize ventilator induced lung injury and improve outcome. Tidal volume (VT), positive end-expiratory pressure (PEEP), respiratory rate (RR), plateau pressures as well as inspiratory oxygen are the main parameters to set mechanical ventilation. Recently, the driving pressure (∆P), i.e., the difference of the plateau pressure and end-expiratory pressure of the respiratory system or of the lung, has been proposed as a key role parameter to optimize mechanical ventilation parameters. The ∆P depends on the VT as well as on the relative balance between the amount of aerated and/or overinflated lung at end-expiration and end-inspiration at different levels of PEEP. During surgery, higher ∆P, mainly due to VT, was progressively associated with an increased risk to develop post-operative pulmonary complications; in two large randomized controlled trials the reduction in ∆P by PEEP did not result in better outcome. In non-ARDS patients, ∆P was not found even associated with morbidity and mortality. In ARDS patients, an association between ∆P (higher than 13-15 cmH2O) and mortality has been reported. In several randomized controlled trials, when ∆P was minimized by the use of higher PEEP with or without recruitment manoeuvres, this strategy resulted in equal or even higher mortality. No clear data are currently available about the interpretation and clinical use of ∆P during assisted ventilation. In conclusion, ∆P is an indicator of severity of the lung disease, is related to VT size and associated with complications and mortality. We advocate the use of ∆P to optimize individually VT but not PEEP in mechanically ventilated patients with and without ARDS.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.