• Chest · May 2018

    Observational Study

    Radiation Exposure in the Medical ICU: Predictors and Characteristics.

    • Sudhir Krishnan, Ajit Moghekar, Abhijit Duggal, Jagadeesh Yella, Shraddha Narechania, Vidhya Ramachandran, Atul Mehta, Fatima Adhi, Vijayan Anil Kumar Changarath AKC Mayo Clinic, Rochester, MN., Xiaozhen Han, Xiaofeng Wang, Frank Dong, Charles Martin, and Jorge Guzman.
    • Cleveland Clinic Foundation, Cleveland, OH. Electronic address: krishsn2@ccf.org.
    • Chest. 2018 May 1; 153 (5): 1160-1168.

    BackgroundPatients admitted to the medical ICU (MICU) are often subjected to multiple radiologic studies. We hypothesized that some endure radiation dose exposure (cumulative effective dose [CED]) in excess of annual US federal occupational health standard limits (CED ≥ 50 mSv) and 5-year cumulative limit (CED ≥ 100 mSv). We also evaluated the correlation of CED with Acute Physiology and Chronic Health Evaluation (APACHE) III score and other clinical variables.MethodsRetrospective observational study conducted in an academic medical center involving all adult admissions (N = 4,155) to the MICU between January 2013 and December 2013. Radiation doses from ionizing radiologic studies were calculated from reference values to determine the CED.ResultsThree percent of admissions (n = 131) accrued CED ≥ 50 mSv (1% [n = 47] accrued CED ≥ 100 mSv). The median CED was 0.72 mSv (interquartile range, 0.02-5.23 mSv), with a range of 0.00 to 323 mSv. Higher APACHE III scores (P = .003), longer length of MICU stay (P < .0001), sepsis (P = .03), and gastrointestinal disorders and bleeding (P < .0001) predicted higher CED in a multivariable linear regression model. Patients with gastrointestinal bleeding and disorders had an odds ratio of 21.05 (95% CI, 13.54-32.72; P < .0001) and 6.94 (95% CI, 3.88-12.38; P < .0001), respectively, of accruing CED ≥ 50 mSv in a multivariable logistic regression model. CT scan and interventional radiology accounted for 49% and 38% of the total CED, respectively.ConclusionsPatients in the MICU are exposed to radiation doses that can be substantial, exceeding federal annual occupational limits, and in a select subset, are > 100 mSv. Efforts to justify, restrict, and optimize the use of radiologic resources when feasible are warranted.Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…