• Resuscitation · Nov 2002

    Comparative Study

    Defibrillation threshold and cardiac responses using an external biphasic defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets.

    • Cheryl R Killingsworth, Sharon B Melnick, Fred W Chapman, Robert G Walker, William M Smith, Raymond E Ideker, and Gregory P Walcott.
    • Cardiac Rhythm Management Laboratory, Department of Medicine, Division of Cardiovascular Diseases, University of Alabama at Birmingham, 1670 University Boulevard, B140 Volker Hall, Birmingham, AL 35294, USA. crk@crml.uab.edu
    • Resuscitation. 2002 Nov 1; 55 (2): 177-85.

    AbstractBefore recommendations for using an automatic external defibrillator on pediatric patients can be made, a protocol for the energy of a biphasic waveform energy dosing needs to be determined that will allow ventricular defibrillation of 8 year olds while causing only a minimal amount of cardiac damage to infants. Pediatric- and adult-sized electrode patches were alternately applied to 10 isoflurane-anesthetized piglets weighing 3.8-20.1 kg to approximate the body weights of newborns to children < 8 years old. The defibrillation threshold (DFT) was determined for biphasic truncated exponential waveform shocks. Additional shocks, varying from the DFT to 360 Joules (J), were delivered during sinus rhythm or following 30 s of ventricular fibrillation (VF). The DFT was 2.4+/-0.81 and 2.1+/-0.65 J/kg for pediatric and adult patches, respectively (P = N.S.). The change in left ventricular (LV) dP/dt from baseline as a function of shock strength was significantly different at 1 and 10 s after shocks of increasing energy that were delivered in sinus rhythm, and 1, 10, 20, and 30 s after defibrillation shocks. There was no significant difference in LV dP/dt with increasing shock energy at 60 s with either patch size. The time to return of sinus rhythm, ST-segment deviation, and cardiac output were also not significantly different from baseline 60 s following shocks of up to 360 J delivered during sinus rhythm or VF with either patch. The same amount of energy delivered with a biphasic external defibrillator successfully defibrillated VF whether adult or pediatric patches were used. Cardiac rhythm and hemodynamic variables were unaltered at 60 s after shocks delivered at energies of up to 360 J. These data suggest that there is a substantial safety margin above a DFT strength shock for this biphasic waveform in piglets.Copyright 2002 Elsevier Science Ireland Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.