-
- Maher Saqqur, Mohamed Ibrahim, Ken Butcher, Khurshid Khan, Derek Emery, Dulka Manawadu, Carol Derksen, Brenda Schwindt, and Ashfaq Shuaib.
- Division of Neurology, Department of Medicine, University of Alberta, Edmonton, AB, Canada.
- J Neuroimaging. 2013 Jul 1;23(3):460-5.
BackgroundCollateral flow augmentation using partial aortic occlusion may improve cerebral perfusion in acute stroke. We assessed the effect of partial aortic occlusion on arterial flow velocities of acute stroke patients.MethodsPatients with neurological deficits following thrombolysis were treated with partial aortic occlusion. Transcranial Doppler ultrasound (TCD) was used to measure arterial flow velocities at baseline, before and during balloon inflation. The augmented mean flow velocity (MFV), peak systolic velocity (PSV), and end diastolic velocity flow percentages (aMFV%, aPSV%, aEDV%) were calculated and compared based on outcome.ResultsOf 11 patients, 3 did not have a temporal window and thus were excluded from our analysis. Six of the remaining 8 patients had middle cerebral artery (MCA) occlusions; the final 2 had terminal internal carotid artery (TICA) occlusions. Three of these 8 patients had good outcome at 90 days (mRS < 3). Before intra-aortic balloon inflation (IABI), the mean affected artery MFV was 23 ± 11 cm/s; during the procedure it was 26 ± 12 cm/s (P = .2). Mean affected artery PSV at baseline and during balloon inflation were 37 ± 16 and 46 ± 23, respectively (P = .1). Mean augmented affected artery MFV% in patients with good long-term outcome was 65.4 ± 46, while the result in those with poor outcome was -3.7 ± 21 (P = .03). Three patients developed anterior cross-filling, and of these 2 had good long-term outcome.ConclusionTCD monitoring of patients treated with IABI may help in predicting outcome in this novel device.Copyright © 2012 by the American Society of Neuroimaging.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.