Journal of anesthesia · Jun 2010
Can intraoperative TEE correctly measure residual shunt after surgical repair of ventricular septal defects?
- Satoshi Kurokawa, Takayuki Honma, Miki Taneoka, Hidekazu Imai, Hiroshi Baba, and Minoru Nomura.
- Department of Anesthesiology, Faculty of Medicine, Tokyo Women's Medical University, 8-1 Kawadacho, Shinjuku-ku, Tokyo 162-8666, Japan. satokuro@sea.plala.or.jp
- J Anesth. 2010 Jun 1; 24 (3): 343-50.
PurposeNo groups have yet succeeded in identifying the need for re-repair of residual shunt after surgical repair of ventricular septal defect (VSD) based on quantitative evaluation of the ratio of the pulmonary blood flow to the systemic blood flow (Qp/Qs) by transesophageal echocardiography (TEE). Hence, we studied the accuracy of Qp/Qs as estimated by intraoperative TEE.MethodsTwenty-six patients undergoing VSD closure were studied. After separation from the cardiopulmonary bypass, the presence and severity of residual leakage was evaluated by color Doppler image, and the Qp/Qs (TEE-derived Qp/Qs) was calculated by measuring the vessel diameter and the velocity-time integral of the flow profiles in the main pulmonary artery and left ventricular outflow tract. Transthoracic echocardiography (TTE) was performed at pre-discharge and at 6-12 months after the correction to confirm the presence and severity of residual leakage.ResultsTEE detected only minor leakage, with no indication for re-repair, in 8 of the 26 patients. Nevertheless, TEE-derived Qp/Qs varied from 0.57 to 2.07 and were incorrect in 17 patients (65.4%). This meant that when TEE-derived Qp/Qs was outside the acceptable range, the patient was judged not to be in need of re-repair. TTE at pre-discharge confirmed trivial leakage in 3 patients in whom TEE had also identified similar leakages. These leakages were not observed at the follow-up TTE.ConclusionTEE-derived Qp/Qs lacks the accuracy required to play a crucial role in quantitatively measuring the severity of residual shunt, while two-dimensional TEE can reliably detect residual leakage after VSD closure and lead to optimal judgment on the need for re-repair.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.