• Injury · Nov 2019

    Ankle joint contact loads and displacement in syndesmosis injuries repaired with Tightropes compared to screw fixation in a static model.

    • Eric Quan Pang, Katherine Bedigrew, Ariel Palanca, Anthony W Behn, Kenneth J Hunt, and Loretta Chou.
    • Stanford University Medical Center, Department of Orthopaedic Surgery, 300 Pasteur Drive, Room R144, Stanford, CA, USA. Electronic address: eric.pang@duke.edu.
    • Injury. 2019 Nov 1; 50 (11): 1901-1907.

    BackgroundThe effect of syndesmotic fixation on restoration of pressure mechanics in the setting of a syndesmotic injury is largely unknown. The purpose of this study is to examine the contact mechanics of the tibiotalar joint following syndesmosis fixation with screws versus a flexible fixation device for complete syndesmotic injury.MethodsSix matched pairs of cadaveric below knee specimens were dissected and motion capture trackers were fixed to the tibia, fibula, and talus and a pressure sensor was placed in the tibiotalar joint. Each specimen was first tested intact with axial compressive load followed by external rotation while maintaining axial compression. Next, syndesmotic ligaments were sectioned and randomly assigned to repair with either two TightRopes® or two 3.5 mm cortical screws and the protocol was repeated. Mean contact pressure, peak pressure, reduction in contact area, translation of the center of pressure, and relative talar and fibular motion were calculated. Specimens were then cyclically loaded in external rotation and surviving specimens were loaded in external rotation to failure.ResultsNo differences in pressure measurements were observed between the intact and instrumented states during axial load. Mean contact presure relative to intact testing was increased in the screw group at 5 Nm and 7.5 Nm torque. Likewise, peak pressure was increased in the TightRope group at 7.5 Nm torque. There was no change in center of pressure in the TightRope group at any threshold; however, at every threshold tested there was significant medial and anterior translation in the screw group relative to the intact state.ConclusionEither screws or TightRope fixation is adequate with AL alone. With lower amounts of torque, the TightRope group appears to have contact and pressure mechanics that more closely match native mechanics.Copyright © 2019 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…