• Clin Neurophysiol · Jul 2004

    Comparative Study Clinical Trial

    A new non-invasive method for recording the electro-olfactogram using external electrodes.

    • Liwei Wang, Churunal Hari, Lixin Chen, and Tim Jacob.
    • School of Biosciences, Cardiff University, Museum Avenue, Cardiff CF10 3US, UK.
    • Clin Neurophysiol. 2004 Jul 1; 115 (7): 1631-40.

    ObjectiveThe aim of this investigation was to explore the possibility of recording the electro-olfactogram (EOG) using external electrodes placed on the root of the nose on either side of the bridge and at the medial termination of the eyebrows. The EOG is considered to be the summated generator potential of olfactory receptor cells and therefore represents peripheral olfactory events. Recording of human EOG is technically difficult due to poor access to the olfactory mucosa and the nasal irritation is tolerated by few subjects.MethodsThe evoked potentials at these sites in response to two odourants, n-amyl acetate and benzaldehyde, were recorded simultaneously with the EOG, recorded conventionally with an intranasal electrode, and the olfactory event-related potential (OERP) recorded using scalp electrodes.ResultsThe extranasal potential recorded at the root of the nose, 0.5-1 cm below the nasion, 1 cm from the ridge and ipsilateral with the stimulus, had the highest degree of correlation with the intranasal EOG. We refer to this site as N1 (left side) and N2 (right side). Further analysis demonstrated that the latency, the time constant of the rising phase and the amplitude of the evoked potential recorded at N1 also had a higher correlation coefficient with the EOG than did those potentials recorded at other sites. Statistical analysis indicated that the latency and time constant of the response recorded externally at N1 were the same as those of the EOG recorded intranasally.ConclusionsWe conclude that an olfactory evoked potential, with many of the characteristics of the EOG recorded from the olfactory mucosa, can be recorded externally at a site close to the bridge of the nose.SignificanceThis non-invasive method of recording the EOG will have benefits for the objective assessment of olfactory function.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…