-
Multicenter Study
Unstable Proximal Femur Fractures Treated With Proximal Femoral Locking Plates: A Retrospective, Multicenter Study of 111 Cases.
- Cory A Collinge, Robert Hymes, Michael Archdeacon, Phillip Streubel, William Obremskey, Timothy Weber, J Tracy Watson, David Lowenberg, and Members of the Proximal Femur Working Group of the Southeast Trauma Consortium.
- *Harris Methodist Fort Worth Hospital, Fort Worth, TX; †Inova Fairfax Hospital, VA; ‡University of Cincinnati Orthopaedics, Cincinnati, OH; §Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, NE; ‖Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN; ¶OrthoIndy at St. Vincent Indianapolis, Indianapolis, IN; **Department of Orthopaedic Surgery, Saint Louis University, St. Louis, MO; and ††Stanford University Medical Center, Redwood City, CA.
- J Orthop Trauma. 2016 Sep 1; 30 (9): 489-95.
ObjectivesA few small case series have found that proximal femur fractures treated with a proximal femur locking plate (PFLP) have experienced more failures than expected. The purpose of this study was to review the clinical results of patients with acute, unstable proximal femur fractures treated with proximal femoral locking plates in a large, multicenter patient cohort.DesignThis is a retrospective clinical study.SettingThe study included patients from 12 regional trauma centers and tertiary referral hospitals.PatientsOne hundred eleven consecutive patients with unstable proximal femur fractures stabilized with a PFLP and having required clinical and radiographic follow-up at a minimum of 12 months after injury.InterventionSurgical repair of an unstable proximal femur fracture with a PFLP.Main Outcome MeasurementsTreatment failures (failure of fixation, nonunion, and malunion) and need for revision surgery.ResultsForty-six patients (41.4%) experienced a major treatment failure, including failed fixation with or without nonunion (39), surgical malalignment or malunion (18), deep infection (8), or a combination of these. Thirty-eight (34%) patients underwent secondary surgeries, including 30 for failed fixation, nonunion, or both. Treatment failure was found to occur at a significantly higher rate in patients with major comorbidities, in femurs repaired in varus malalignment, and using specific plate designs.ConclusionsProximal femoral locking plates are associated with a high complication rate, frequently requiring revision or secondary surgeries in the treatment of unstable proximal femur fractures. Given the high complication rate with PFLPs, careful attention to reduction, use of a PFLP implant, and consideration should be given to alternative implants or fixation techniques when appropriate.Level Of EvidenceTherapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.