• Sleep · Jun 2011

    Air leak is associated with poor adherence to autoPAP therapy.

    • Alexandra Valentin, Shyam Subramanian, Stuart F Quan, Richard B Berry, and Sairam Parthasarathy.
    • Southern Arizona Veterans Administration Healthcare System, Tucson, AZ, USA.
    • Sleep. 2011 Jun 1; 34 (6): 801-6.

    Study ObjectivesTo our knowledge, a systematic study of the effect of air leak on adherence to auto-titrating positive airway pressure (autoPAP) therapy has not been reported. We hypothesized that in patients with obstructive sleep apnea (OSA), greater levels of air leak were associated with poor adherence to autoPAP therapy.DesignRetrospective cohort studySettingAcademic CenterParticipantsNinety-six consecutive patients with high probability for OSA.InterventionsN/A.MeasurementsPatients with OSA received 1 week of autoPAP therapy following which both adherence data and air leak information was downloaded from the device. Continuous positive airway pressure (CPAP) therapy was issued for a 5-week period with pressure determined by 90th percentile of that delivered during autoPAP therapy. Adequate adherence was defined as average usage > 4 h per night on all nights.ResultsForty-three patients were adherent to autoPAP therapy (350 ± 67[SD] min/day), whereas 53 patients were not (122 ± 65 min/day; P < 0.0001). Air leak that was adjusted for pressure delivered was greater in non-adherent patients (7.0 ± 3.5 L/min/cm H(2)O) than that in adherent patients (4.9 ± 1.7 L/min/cm H(2)O; P < 0.0001). Greater residual respiratory events (measured as autoPAP-derived hypopnea index) and proportion of time spent at large leak levels were associated with non-adherence. Patients who were adherent to autoPAP therapy received higher average therapeutic pressures from the autoPAP device than non-adherent patients. Multivariate logistic regression revealed that higher levels of air leak were associated with non-adherence to autoPAP therapy (odds ratio 1.43; 95% CI, 1.03, 1.98; P = 0.03). Moreover, adherence to autoPAP therapy was strongly correlated with subsequent adherence to CPAP therapy (R(2) = 0.74; P < 0.0001).ConclusionAir leak was associated with poor adherence to autoPAP therapy. We speculate that air leak could be a potential target for future studies aimed at enhancing adherence to autoPAP therapy.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.