- Andrzej Przybylski, Joanna Zakrzewska-Koperska, Aleksander Maciag, Paweł Derejko, Michał Orczykowski, Lukasz Szumowski, and Franciszek Walczak.
- Institute of Cardiology, 04-628 Warsaw, Poland. aprzybylski@ikard.pl
- Kardiol Pol. 2009 May 1; 67 (5): 505-11.
BackgroundThe aim of remote monitoring of implantable cardioverter-defibrillators (ICD) is to increase the patient's safety by early detection of technical or medical malfunctions and decrease the number of follow-up visits.AimTo evaluate the feasibility and reliability of internet-based home monitoring of ICD recipients in Poland.MethodsTwenty-seven patients with ICD with remote monitoring options were evaluated; 20 (74%) patients had a single chamber ICD, 6 (22%) patients had a dual chamber ICD and one had an ICD with a resynchronisation therapy option. Medical and technical events reported by the remote monitoring system as well as interruptions in monitoring longer than 14 days were analysed.ResultsThe patients were followed for 12.7 +/- 10.5 months. Two of them died because of heart failure (6 and 13 months after ICD implantation, respectively). The remote monitoring system reported medical events in 13 (48%) patients. In total, we received 32 event reports (from 1 to 19 per patient, mean 2.6) which were generated due to the detection of ventricular tachycardia (VT) (17 events in 9 patients), ventricular fibrillation (VF) (9 episodes in 6 patients), ineffective defibrillation with the maximal energy (5 reports in 3 patients) and supraventricular tachycardia in the VT detection window (1). Two patients had more than 3 VT/VF episodes during 24 h. There were no reports on technical abnormalities of the ICD system. Interruptions in home monitoring longer than 14 days occurred in 5 (18.5%) patients and lasted 2 to 14 weeks (mean 2.8 +/- 7.1). The longest break was caused by the patient's stay abroad. The remaining interruptions were caused by: journeys (5 episodes), hospitalisations (4), and a temporary stay in a place without sufficient GSM coverage (3). During the follow-up period there were no interruptions in monitoring caused by transmitter or ICD failure. All data received by the home monitoring system were confirmed during the follow-up visits.ConclusionRemote monitoring of ICD recipients in Poland does not present technical difficulties and enables early detection of serious events in ICD patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.