    [Continuous intravascular blood gas analysis. Clinical evaluation of a new fiber optic monitor].

    • M Haller, E Kilger, J Briegel, J Polasek, H Forst, J Groh, and K Peter.
    • Institut für Anaesthesiologie, Ludwig-Maximilians-Universität, München.
    • Anaesthesist. 1994 Oct 1; 43 (10): 642-7.

    AbstractContinuous monitoring of blood gases and pH could add substantially to patient safety. During the last decade, efforts have been made to develop continuous optochemical blood gas sensors. The initial evaluation of such fibreoptic-based systems showed major patient-interface problems [11]. We evaluated a new intra-arterial blood gas monitoring system (PB3300, Puritan-Bennett, Carlsbad CA) under routine clinical conditions. METHODS. After institutional review board approval and with written informed consent, 38 sensors were tested in 25 patients with acute respiratory failure (e.g., the acute respiratory distress syndrome, complications after lung transplantation). Two conventional bench-top blood gas analysers (ABL 520 and ABL 300, Radiometer, Copenhagen) served as criterion standards. The mean differences (bias) and standard deviations (SD) of the differences (precision) were calculated according to the method of Bland and Altman [2]. In addition, linear regression analysis and correlation coefficients were calculated. The quality of blood pressure tracings was assessed using a grading system. RESULTS. The median sensor lifetime was 81.3 h; 869 blood samples (median 14 per sensor) were analysed for the comparison of continuous and conventional blood gas analysis. The ranges for measured parameters were: pH: 6.92 to 7.55; PCO2: 20 to 83 torr; PO2: 31 to 518 torr. The mean differences (SD) were: pH: -0.03 (0.03) or -0.4 (0.4)%; PCO2: -2.6 (4.1) torr or -6.9 (10.9)%; PO2: -3.4 (10.5) torr or -2.9 (7.0)%. The results of linear regression analysis and the correlation coefficients are depicted in Table 2. The mean grade of blood pressure tracings was satisfactory for the clinical setting. CONCLUSIONS. The continuous blood gas monitor is sufficiently accurate and precise for clinical use. Bias and precision are better than those known from former studies evaluating fibreoptic blood gas monitors under experimental conditions [7]. Cost-effectiveness was not an issue of this study.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.