    [Preclinical control of intubation and artificial respiration. Animal experiment and literature review].

    • G Petroianu, W Maleck, W F Bergler, K Ellinger, P M Osswald, and R Rüfer.
    • Fakultät für klinische Medizin Mannheim, Universität Heidelberg.
    • Anaesthesist. 1995 Sep 1; 44 (9): 613-23.

    AbstractOesophageal malposition of an endotracheal tube is among the leading causes of anaesthesia incidents. While clinical manoeuvres for detection of tube malposition are unreliable, monitoring (i.e. capnography) can prevent such incidents. The problem is particularly important in prehospital care, where capnography is not (yet) widely available. We tested three devices used for differentiating oesophageal from endotracheal intubation: 1. Non-CO2-dependent Oesophageal Detector Device (ODD) as described by Pollard and Wee, 2. Semi-quantitative chemical disposable capnometer EasyCAP (Nellcor), 3. Non-quantitative infrared miniaturised capnometer MiniCAP (MSA). METHODS. 50 anaesthetised minipigs were intubated with a Magill tube. An identical additional tube was placed in the oesophagus. The cuffs of both tubes were inflated. Unexperienced personnel (students, laboratory technicians) were asked to determine the position of one of the tubes by using one of the devices according to the randomisation plan. The decision had to be taken within 30 s. Using the ODD, the proband first injected 100 ml air into the lung (or stomach) and then tried to aspirate the same volume. EasyCAP and MiniCAP were used according to manuals. RESULTS. Each device was used 25 times with a tracheal tube and 25 times with an oesophageal tube. All tube position identifications were correct. When ventilating the oesophagus/stomach for capnometric control, regurgitation into the tube occurred six times (five times with the EasyCAP and once with the MiniCAP). In these cases, the decision was based on this occurrence and not on the display of the device. While using the ODD no regurgitation occurred. CONCLUSION. These devices are useful for preclinical practice. According to the literature and our experience, the ODD is superior for the initial control of tube position, especially in cardiac arrest. Capnometry is needed, however, for continuous control of ventilation.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.