• Eur J Trauma Emerg Surg · Oct 2021

    Antegrade versus retrograde screw fixation of anterior column acetabular fractures: a biomechanical in vitro study.

    • Georg Osterhoff, Dag Wulsten, Satish Babu, Mark Heyland, and Carlotta Pari.
    • Department of Orthopaedics, Trauma and Plastic Surgery, University Hospital Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany. georg.osterhoff@medizin.uni-leipzig.de.
    • Eur J Trauma Emerg Surg. 2021 Oct 1; 47 (5): 1307-1312.

    BackgroundTo compare the mechanical strength of antegrade versus retrograde lag screw fixation of anterior column acetabular fractures.MethodsStandardised anterior column fractures were created in synthetic pelvis models and stabilised by either antegrade (ANTE, n = 4) or retrograde (RETRO, n = 4) anterior column screw fixation. In a validated setup, a cyclic loading protocol was applied with increasing axial force (750 cycles, 250-750 N) followed by load to failure. Construct survival, energy absorbed, construct stiffness, and load to failure were assessed. Descriptive and opto-metric methods were used to describe the mode of failure.ResultsAll constructs failed with loads below 1500 N. With regard to energy absorbed until failure, the ANTE group resisted to 3.763 × 105 N*cycles (range 3.760 × 105-3.763 × 105) and the RETRO group to 3.762 × 105 N*cycles (range 3.761 × 105-3.765 × 105; p = 1.0). The load to failure was 1254 N (range 977-1299) in the ANTE group and 1234 N (range 1087-1456) in the RETRO group (p = 1.0). Construct stiffness with 250 N was not different between the two groups (ANTE 192 N/mm vs. RETRO 215 N/mm, p = 0.486). In all samples, the mode of failure was a transiliac fracture with screw breakout due to rotation of the pubic fragment around the axis of the screw with a range of rotational motion [ROM] during cyclic testing of 0.96° in one ANTE sample and 0.82° in one RETRO sample for 750 N, and ROM at failure of 2.53° in one ANTE sample and 2.23° in one RETRO sample. There was some plastic deformation of the screws in all cases but no breakage.ConclusionsIn this in vitro mechanical study, antegrade screw fixation of an anterior column acetabular fracture was not different in construct survival, load to failure, stiffness, and mode of failure when compared to retrograde screw fixation.© 2019. Springer-Verlag GmbH Germany, part of Springer Nature.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…