• Endoscopy · May 2016

    Practice Guideline

    Removal of foreign bodies in the upper gastrointestinal tract in adults: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

    • Michael Birk, Peter Bauerfeind, Pierre H Deprez, Michael Häfner, Dirk Hartmann, Cesare Hassan, Tomas Hucl, Gilles Lesur, Lars Aabakken, and Alexander Meining.
    • Department of Gastroenterology, Universitätsklinikum Ulm, Ulm, Germany.
    • Endoscopy. 2016 May 1; 48 (5): 489-96.

    AbstractThis Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the removal of foreign bodies in the upper gastrointestinal tract in adults. Recommendations Nonendoscopic measures 1 ESGE recommends diagnostic evaluation based on the patient's history and symptoms. ESGE recommends a physical examination focused on the patient's general condition and to assess signs of any complications (strong recommendation, low quality evidence). 2 ESGE does not recommend radiological evaluation for patients with nonbony food bolus impaction without complications. We recommend plain radiography to assess the presence, location, size, configuration, and number of ingested foreign bodies if ingestion of radiopaque objects is suspected or type of object is unknown (strong recommendation, low quality evidence). 3 ESGE recommends computed tomography (CT) scan in all patients with suspected perforation or other complication that may require surgery (strong recommendation, low quality evidence). 4 ESGE does not recommend barium swallow, because of the risk of aspiration and worsening of the endoscopic visualization (strong recommendation, low quality evidence). 5 ESGE recommends clinical observation without the need for endoscopic removal for management of asymptomatic patients with ingestion of blunt and small objects (except batteries and magnets). If feasible, outpatient management is appropriate (strong recommendation, low quality evidence). 6 ESGE recommends close observation in asymptomatic individuals who have concealed packets of drugs by swallowing ("body packing"). We recommend against endoscopic retrieval. We recommend surgical referral in cases of suspected packet rupture, failure of packets to progress, or intestinal obstruction (strong recommendation, low quality evidence). Endoscopic measures 7 ESGE recommends emergent (preferably within 2 hours, but at the latest within 6 hours) therapeutic esophagogastroduodenoscopy for foreign bodies inducing complete esophageal obstruction, and for sharp-pointed objects or batteries in the esophagus. We recommend urgent (within 24 hours) therapeutic esophagogastroduodenoscopy for other esophageal foreign bodies without complete obstruction (strong recommendation, low quality evidence). 8 ESGE suggests treatment of food bolus impaction in the esophagus by gently pushing the bolus into the stomach. If this procedure is not successful, retrieval should be considered (weak recommendation, low quality evidence). The effectiveness of medical treatment of esophageal food bolus impaction is debated. It is therefore recommended, that medical treatment should not delay endoscopy (strong recommendation, low quality evidence). 9 In cases of food bolus impaction, ESGE recommends a diagnostic work-up for potential underlying disease, including histological evaluation, in addition to therapeutic endoscopy (strong recommendation, low quality evidence). 10 ESGE recommends urgent (within 24 hours) therapeutic esophagogastroduodenoscopy for foreign bodies in the stomach such as sharp-pointed objects, magnets, batteries and large/long objects. We suggest nonurgent (within 72 hours) therapeutic esophagogastroduodenoscopy for medium-sized blunt foreign bodies in the stomach (strong recommendation, low quality evidence). 11 ESGE recommends the use of a protective device in order to avoid esophagogastric/pharyngeal damage and aspiration during endoscopic extraction of sharp-pointed foreign bodies. Endotracheal intubation should be considered in the case of high risk of aspiration (strong recommendation, low quality evidence). 12 ESGE suggests the use of suitable extraction devices according to the type and location of the ingested foreign body (weak recommendation, low quality evidence). 13 After successful and uncomplicated endoscopic removal of ingested foreign bodies, ESGE suggests that the patient may be discharged. If foreign bodies are not or cannot be removed, a case-by-case approach depending on the size and type of the foreign body is suggested (weak recommendation, low quality evidence). © Georg Thieme Verlag KG Stuttgart · New York.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.