• J Clin Monit Comput · May 1998

    Applying human factors to the design of medical equipment: patient-controlled analgesia.

    • L Lin, R Isla, K Doniz, H Harkness, K J Vicente, and D J Doyle.
    • Department of Mechanical & Industrial Engineering, University of Toronto, Institute of Biomedical Engineering, Ontario, Canada.
    • J Clin Monit Comput. 1998 May 1; 14 (4): 253-63.

    ObjectiveMedical instruments commonly have poorly designed user interfaces that promote human errors with life-threatening consequences. The primary hypothesis of this study was that a specific user interface could be made safer and more efficient if redesigned using human factors techniques and principles.MethodsThe user interface of a commercially available patient-controlled analgesia (PCA) pump, the Abbott Lifecare 4100 PCA Plus II infuser, was evaluated using a cognitive task analysis of bench tests and field observations. Based on this analysis, the user interface was redesigned. Important elements of the new design include a dialog structure with fewer steps, a dialog overview showing the user's location in the programming sequence, better command feedback, easier error recovery, and clearer labels and messages. The changes were evaluated by comparing a computer prototype of the new interface with a computer simulation of the old one. Twelve student nurses performed six programming tasks with each interface. Task completion time, number of errors, and subjective mental workload were collected for each trial.ResultsThe results showed significantly faster programming times (F(1,11) = 6.85, P < 0.025), lower mental workload ratings (chi2(1) = 4.45, p < 0.025, one-tailed), and fewer errors (chi2(1) = 3.33, p < 0.05, one-tailed) with the new interface.ConclusionAdopting a human factors approach to redesigning the PCA interface led to significantly faster, easier, and more reliable performance. These findings have important implications for improving the design of other computer-based medical equipment.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.