    Influence of the reference gas of paramagnetic oxygen analyzers on nitrogen concentrations during closed-circuit anesthesia.

    • J F Hendrickx, A A van Zundert, and A M de Wolf.
    • Department of Anesthesiology, Intensive Care and Pain Therapy, Catharina Hospital, Eindhoven, The Netherlands.
    • J Clin Monit Comput. 1998 Aug 1; 14 (6): 381-4.

    AbstractNitrogen (N2) may accumulate to unacceptable levels during closed-circuit anesthesia (CCA) when the sampled gases are redirected to the anesthesia circuit, because many gas analyzers entrain air as a reference gas to calibrate for oxygen analysis. Using oxygen instead of air as the reference gas for paramagnetic oxygen analysis could attenuate N2 accumulation. Forty-three adult ASA physical status I-III patients undergoing a variety of peripheral and abdominal procedures were assigned to one of two groups, depending on the reference gas used by a paramagnetic oxygen analyzer, either air (group I, n = 23) or oxygen (group II, n = 20). Gases sampled by the multigas analyzer were redirected to the anesthesia circuit. End-expired N2 (N2Et) was calculated as "balance gas": (100 - %O2 - %anesthetic vapor - %CO2). N2Et after 55 min (N2Et55min) was correlated with the end-expired N2 concentration when the circuit was closed (N2Et0min) and 5 min (N2Et5min) thereafter. In group I, N2Et accumulated almost linearly over time (t, min): N2Et (%) = 2.47 + 0.61 * t (r2 = 0.999). N2Et0min, N2Et5min, and N2Et55min were 1.3+/-0.8, 5.3+/-1.7, and 35.3+/-5.3%, respectively (mean +/- SD). The correlation (r2) between N2Et55min and N2Et0min was 0.19, and between N2Et55min and N2Et5min it was 0.56. In group II, N2Et increased exponentially: N2Et (%) = 1.01 + 11.9 * (1 - e(-t/43.5)) (r2 = 0.99). N2Et0min, N2Et5min, and N2Et55min were 0.87+/-0.93, 2.6+/-1.5, and 10.1+/-2.9%, respectively. The correlation (r2) between N2Et55min and N2Et0min was 0.04, and between N2Et55min and N2Et5min it was 0.40. We conclude that paramagnetic oxygen analyzers that use oxygen as the reference gas significantly attenuate N2 accumulation during CCA, which may reduce the need for frequent flushing of the anesthesia system, may provide more constant oxygen and nitrous oxide concentrations, and may simplify pharmacokinetic studies of potent inhaled anesthetics.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.