• J Clin Monit Comput · Aug 1998

    Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices.

    • K Roske, B Foitzik, R R Wauer, and G Schmalisch.
    • Department of Neonatology (Charité), Humboldt University Berlin, Germany.
    • J Clin Monit Comput. 1998 Aug 1; 14 (6): 413-20.

    ObjectiveVentilatory measurements in ventilated newborns are increasingly used to monitor and to optimize mechanical ventilation. The aim of this study was to compare the accuracy of volume measurements by different instruments using standardized laboratory conditions.MethodsThe accuracy of displayed volume values of different commercial devices (Bicore CP-100, Ventrak 1500, Ventrak 1550, Babylog 8000, PEDS IV and SensorMedics 2600) was investigated using adjustable calibration syringes (volume range 2-60 ml, breathing rates 30/min-60/min) and humidified (>95%), heated (35 degrees C) breathing gas with adjustable FIO2 (0.21-1.0). The pneumotach and also the tubes were placed within an incubator (37 degrees C).ResultsThe relative volume error of all devices was in conformity with clinically allowed tolerances (Bicore CP-100 6.4+/-0.5% (mean +/- SD), Ventrak 1500 3.6+/-4.2%, Ventrak 1550 6.5+/-2.7%, Babylog 8000 -5.5+/-1.5%, PEDS IV -4.0+/-1.4%, SensorMedics 2600 3.5+/-1.75%) for the measuring range studied (10 ml < V < 60 ml, rate 30-60/min, FIO2 = 0.21). Unacceptable errors were obtained for volumes lower than 10 ml with Bicore CP-100 (-28.5+/-26%) and PEDS IV (-10.3+/-3.4%). Changes in FIO2 had an important influence on volume measurements and only the SensorMedics 2600 and the PEDS IV corrected properly for FIO2 changes.ConclusionMost of the currently available neonatal spirometry devices allow sufficiently accurate volume measurements in the range of 10-60 ml and at frequencies between 30-60/min provided that an increased FIO2 is taken into account.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…