• Arch. Pathol. Lab. Med. · Apr 2017

    New-Generation Thromboelastography: Comprehensive Evaluation of Citrated and Heparinized Blood Sample Storage Effect on Clot-Forming Variables.

    • Joao D Dias, Elaine I Haney, Blesy A Mathew, Carlos G Lopez-Espina, Adrian W Orr, and Mark A Popovsky.
    • From the Department of Clinical Marketing, Haemonetics SA, Signy, Switzerland (Dr Dias); the Department of Scientific Research & Development, Haemonetics Corporation, Rosemont, Illinois (Mss Haney and Mathew and Mr Lopez-Espina); and the Department of Medical & Clinical Affairs, Haemonetics Corporation, Braintree, Massachusetts (Mr Orr and Dr Popovsky). Mr Orr is now with Anika Therapeutics Inc, Bedford, Massachusetts. Dr Dias and Ms Haney contributed equally to the design of this manuscript.
    • Arch. Pathol. Lab. Med. 2017 Apr 1; 141 (4): 569-577.

    Context- Thromboelastography (TEG) is a whole blood, real-time analyzer measuring the viscoelastic properties of the hemostasis process and allowing for individualized goal-directed therapy. However, routine use of TEG requires validation of sample storage effect on clot parameters.Objectives- To establish the minimum time required for equilibration time and the maximum time for sample storage for all commercially available TEG tests for the new-generation TEG 6s and to determine how those times compare with the older generation TEG 5000.Design- Citrated and heparinized whole blood samples obtained from 20 healthy donors were analyzed for clot parameters at multiple time points for both the TEG 6s and the TEG 5000. Samples were activated with the citrated multichannel cartridge or the platelet-mapping cartridge in the TEG 6s or with recalcified kaolin in the TEG 5000.Results- All blood samples yielded TEG parameter results within reference ranges and had a tendency toward hypercoagulable profiles with increased storage time. Sample storage resulted in increased platelet inhibition with significant differences at 4 hours in the platelet-mapping cartridge (arachidonic acid percentage of inhibition, P = .002; adenosine diphosphate percentage of inhibition, P = .02).Conclusions- For nonemergent cases or in a central laboratory setting, all tests provided reliable results for up to 4 hours in the citrated multichannel cartridge and for 3 hours for platelet function information in the platelet-mapping cartridge. In emergent/urgent situations in which the sample needs to be run immediately, RapidTEG and functional fibrinogen tests may be preferred.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.