-
- Francisco G Laredo, Antonio G Cantalapiedra, Amalia Agut, José L Pereira, and José Murciano.
- Facultad de Veterinaria, Departamento de Patología Animal, Universidad de Murcia, Murcia, Spain.
- Vet Anaesth Analg. 2001 Jul 1; 28 (3): 161-167.
AbstractObjective To quantify the vapour output of the Komesaroff machine when using sevoflurane and to determine its performance for inducing and maintaining sevoflurane anaesthesia in dogs. Study design Prospective experimental study. Animals Six clinically normal beagles, aged 3-6 years and weighing 20 ± 1.65 kg (mean ± SEM). Methods The first study was performed using five Komesaroff vaporizers to measure the sevoflurane concentration delivered at each tap setting (I to IV) at 5, 10, 15, 20, 25, 30 and 35 minutes. For this study a ventilator was connected to the Komesaroff machine and set to deliver a tidal volume of 250 mL at 10 cycles minute-1; oxygen flow was 100 mL minute-1. A three-litre reservoir bag was attached to the Y-piece connector to act as a lung model. In the second study anaesthesia was induced in dogs with sevoflurane delivered by face-mask mask and carried in 2 L minute-1 100% oxygen and with the vaporizer set at the fully open position. The quality and speed of induction were recorded. After orotracheal intubation, anaesthesia was maintained for 60 minutes with sevoflurane using an oxygen flow of 100 mL minute-1. The dogs were allowed to breathe spontaneously. The respiratory rate (RR), heart rate (HR), oesophageal temperature, systolic (SAP) mean (MAP) and diastolic (DAP) arterial pressure, end-tidal CO2 concentration (Fe'CO2) end-tidal (Fe'SEVO) and peak-inspired (FiSEVO) percentages of sevoflurane, and vaporizer tap setting were recorded every 5 minutes during anaesthesia. Results The delivery of sevoflurane was constant for each vaporizer setting. The mean output of sevoflurane was 0.44 ± 0.01% for setting I, 2.59 ± 0.18% for setting II, 3.28 ± 0.22% for setting III and 3.1 ± 0.5% for setting IV. In the second study, the mean induction time was 7.72 ± 0.60 minutes and the quality of the induction was good in all dogs. The mean vaporizer tap setting for the maintenance of anaesthesia was 3.48 ± 0.12 and the mean values for Fe'SEVO and FiSEVO were 2.42 ± 0.04% and 2.87 ± 0.06%, respectively. The pedal withdrawal reflex persisted throughout anaesthesia. Conclusions It proved impossible to produce surgical anaesthesia with sevoflurane delivered by the Komesaroff machine despite the highest possible sevoflurane concentration being delivered. Clinical relevance Sevoflurane delivered from the Komesaroff machine cannot be relied upon to maintain surgical anaesthesia in spontaneously breathing dogs.Copyright © 2001 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.