• J. Cardiothorac. Vasc. Anesth. · Mar 2020

    Observational Study

    Comparison of ROTEM Sigma to Standard Laboratory Tests and Development of an Algorithm for the Management of Coagulopathic Bleeding in a Tertiary Center.

    • Emmanuelle Scala, Christine Coutaz, Francisco Gomez, Lorenzo Alberio, and Carlo Marcucci.
    • Department of Anesthesiology, Lausanne University Hospital, Lausanne, Switzerland; Division of Hematology and Central Hematology Laboratory, Lausanne University Hospital, Lausanne, Switzerland. Electronic address: emmanuelle.scala@chuv.ch.
    • J. Cardiothorac. Vasc. Anesth. 2020 Mar 1; 34 (3): 640-649.

    ObjectiveThe ROTEM sigma whole blood viscoelastic test uses different technology than the former delta model. Existing ROTEM based algorithms use cutoff values based on the delta model, and cannot be applied to the sigma model. The authors tested sensitivity and specificity of ROTEM sigma parameters to detect specific hemostatic deficiencies and established cutoff values with the aim of developing a treatment algorithm.DesignProspective observational evaluation of diagnostic accuracy.SettingThis study was performed in a tertiary center.ParticipantsBlood samples for standard laboratory tests (SLTs) and ROTEM sigma analysis were obtained from 14 healthy volunteers and 35 patients showing various hemostatic disorders (isolated factor deficiencies, von Willebrand's disease, thrombocytopenia, hypofibrinogenemia, hyperfibrinogenemia, and patients undergoing cardiac surgery).InterventionCorrelation coefficients were calculated between SLTs and ROTEM parameters in the extrinsic pathway activation, intrinsic pathway activation, and extrinsic pathway activation with platelet inhibition tests. Receiver operator characteristics defined the values of ROTEM parameters, which best predict plasma fibrinogen level measured by Clauss method <1.5 g/L and <2.0 g/L, platelet < 50 × 109/L and < 100 × 109/L, prothrombin time (PT) <80% and activated partial thromboplastin time (aPTT) >37 seconds and 1.5 times the upper normal limit.Measurement And Main ResultsThe combination of FIBTEM A5 ≤12 mm and EXTEM A5 ≤44 mm identified a fibrinogen level <1.5 g/L with 100% sensitivity and 77.5% specificity. PLTEM describes the platelet contribution to clot firmness and is calculated as EXTEM - FIBTEM. PLTEM A5 ≤16 mm sensitivity and specificity were 100% and 96.4% for a platelet count < 50 × 109/L. EXTEM coagulation time (CT) >80 seconds had a 25.0% sensitivity and a 100% specificity for a PT <80%. The INTEM CT >204 seconds showed a sensitivity of 75.0% and a specificity of 97.4% for an aPTT >37 and a sensitivity of 100% and a specificity of 80.0% for an aPTT >55 seconds.ConclusionThe authors present the first ROTEM sigma-based algorithm for the treatment of coagulopathic bleeding. The algorithm uses parameters with optimal sensitivity and specificity for critical values of SLTs determined from a heterogenous group of donors.Copyright © 2019 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.