J Clin Monit Comput · Feb 2002
Comparative StudyComparative provocation test of respiratory monitoring methods.
- Mia Folke, Fredrik Granstedt, Bertil Hök, and Håkan Scheer.
- Department of Electrical Engineering, Mälardalens Högskola, Sweden. mia.folke@mdh.se
- J Clin Monit Comput. 2002 Feb 1; 17 (2): 97-103.
ObjectiveThe aim of this study was to compare clinically relevant performance of: 1) a prototype respiratory sensor based on capnometry with two alternative signal receptor fixations, 2) a fiberoptic humidity sensor and 3) human visual observation. Comparative provocation tests were performed on volunteers at the Post-Anesthesia Care Unit at Västerås Central Hospital.MethodsThe experimental tests involved 10 healthy, voluntary test subjects, instructed to intersperse normal breathing with protocol provocations of breath holding, limb and head movements, and nasal oxygen supplement. The signal outputs from the three respiratory monitoring methods were recorded on a personal computer. The signal analysis included visual categorising of the signals and counting breath events. Recognising that none of the methods could act as reference, events were classified as "unanimous," "majority" or "minority" events depending on how many of the three methods that detected a breath.ResultsThe average total recording time was 37 minutes per subject. The respiratory rates varied from 6.5 to 19 breaths per minute, with a mean value of 11.4 breaths/minute. The breath hold duration ranged from 18 to 50 seconds. Discrepancies between the three methods were found in more than 20% of the marked events. The most frequent majority events were due to events not recorded by the observer who, on the other hand, contributed the least to minority events. The provocations made by the subjects during the measurement did not increase the rates of majority and minority events, compared to periods of no provocation. The fiberoptic device exhibited a larger count of minority events but a smaller contribution to majority events than the capnometry prototype.ConclusionsThe capnometry and fiberoptic sensors exhibit differences in responses that may be understood from basic principles. The importance of the physical application of the sensor to the patient was clearly observed. The optimum design remains to be found.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.