Randomized Controlled Trial Comparative Study Clinical TrialOn the dynamic performance of the Abbott Safeset blood-conserving arterial line system.
- R P Woda, R Dzwonczyk, C Buyama, B L Bernacki, and W B Kelly.
- Department of Anesthesiology, The Ohio State University, College of Medicine, Columbus, Ohio 43210-1228, USA.
- J Clin Monit Comput. 1999 May 1; 15 (3-4): 215-21.
ObjectiveCritically ill patients frequently have indwelling arterial lines placed during their Intensive Care Unit stay. The lines are used to monitor blood pressure continuously, administer drugs and to draw blood for a variety of physiologic tests. Several blood-conserving arterial line systems have been developed to eliminate the need to discard blood in the process of obtaining undiluted and uncontaminated blood samples. The purpose of this study was to evaluate the dynamic performance of one such system the Abbott Clinical Care System Safeset blood conserving arterial line system - in comparison to a conventional arterial line system.MethodsWe studied ninety-nine patients who had indwelling arterial lines placed during surgery and who were admitted to our Surgical Intensive Care Unit (SICU). The patients were randomly placed into one of two groups. The control group received a conventional indwelling arterial line system; the experimental group received the Abbott Safeset system. We measured the damping coefficient and resonant frequency daily in order to evaluate and compare the dynamic performance of the two systems. We also measured discard volumes (in the control group) and blood sample sizes during the patients' stays in the SICU.ResultsThe two patient groups were similar in regards to demographics and baseline clinical characteristics. A median 3 ml of blood per draw and 17.5 ml of blood per patient was discarded in purging the conventional arterial line system while, by design, no blood was discarded with the experimental system. There was no difference between the two groups with regard to damping coefficient. Both systems were underdamped. However, the conventional arterial line system had a significantly higher resonant frequency (16.7 Hz) compared to the Safeset system (12.5 Hz).ConclusionsBecause the Abbott Safeset blood-conserving arterial line system is underdamped and has a lower resonant frequency compared to the traditional arterial system, it may overestimate systolic blood pressure, particularly in patients with high heart rates.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.