J Clin Monit Comput · Dec 2004
ReviewPulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.
- Jochanan E Naschitz, Stanislas Bezobchuk, Renata Mussafia-Priselac, Scott Sundick, Daniel Dreyfuss, Igal Khorshidi, Argyro Karidis, Hagit Manor, Mihael Nagar, Elisabeth Rubin Peck, Shannon Peck, Shimon Storch, Itzhak Rosner, and Luis Gaitini.
- Departmentments of Internal Medicine A, Bnai-Zion Medical Center and Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel. naschitz@tx.technion.ac.il
- J Clin Monit Comput. 2004 Dec 1; 18 (5-6): 333-42.
ObjectivePulse transit time (PTT) is the time it takes a pulse wave to travel between two arterial sites. A rela tively short PTT is observed with high blood pressure (BP), aging, arteriosclerosis and diabetes mellitus. Most methods used for measuring the PTT are cumbersome and expensive. In contrast, the interval between the peak of the R-wave on the electrocardiogram and the onset of the corresponding pulse in the finger pad measured by photoplethysmography can be easily measured. We review herein the literature and impart the experience at our institution on clinical applications of R-wave-gated photo-plethysmography (RWPP) as measurement of PTT.MethodsThe MEDLINE data base on clinical applications of RWPP was reviewed. In addition, studies performed in the author's institution are presented.ResultsWhen used as a surrogate for beat-to-beat BP monitoring, RWPP did not meet the level of accuracy required for medical practice (two studies). RWPP produced accurate and reproducible signals when utilized as a surrogate for intra-thoracic pressure changes in obstructive sleep apnea, as well as BP arousals which accompany central sleep apnea (five studies). In estimation of arterial stiffness, RWPP was unsatisfactory (one study). In assessment of cardiovascular reactivity, abnormal values of RWPP were noted in autonomic failure (one study), while disease-specific reactivity patterns were identified utilizing a method involving RWPP (two studies).ConclusionsIn clinical practice, sleep-apnea may be accurately monitored by RWPP. RWPP seems to reflect autonomic influences and may be particularly well-suited for the study of vascular reactivity. Thus, further descriptions of disease-specific cardiovascular reactivity patterns may be possible with techniques based on RWPP. Other clinical uses of RWPP are investigational.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.