Pediatr Crit Care Me · Apr 2020
Achieving Sustainability in Reducing Unplanned Extubations in a Pediatric Cardiac ICU.
- Nina M Censoplano, Cindy S Barrett, Richard J Ing, Kelly Reichert, Michael Rannie, and Jon Kaufman.
- Division of Cardiology, Department of Pediatrics, University of Colorado Anschutz Medical Center, Children's Hospital Colorado, Aurora, CO.
- Pediatr Crit Care Me. 2020 Apr 1; 21 (4): 350-356.
ObjectivesTo determine the incidence of unplanned extubations in a pediatric cardiac ICU in order to prove sustainability of our previously implemented quality improvement initiative. Additionally, we sought to identify risk factors associated with unplanned extubations as well as review the overall outcome of this patient population.DesignRetrospective chart review.SettingPediatric cardiac ICU at Children's Hospital of Colorado on the Anschutz Medical Center of the University of Colorado.PatientsIntubated and mechanically ventilated patients in the cardiac ICU from July 2011 to December 2017.InterventionsNone.Measurements And Main ResultsA total of 2,612 hospitalizations for 2,067 patients were supported with mechanical ventilation. Forty-five patients had 49 episodes of unplanned extubations (four patients > 1 unplanned extubation). The average unplanned extubation rate per 100 ventilator days was 0.4. Patients who had an unplanned extubation were younger (0.09 vs 5.45 mo; p < 0.001), weighed less (unplanned extubation median weight of 3.0 kg [interquartile range, 2.5-4.5 kg] vs control median weight of 6.0 kg [interquartile range, 3.5-13.9 kg]) (p < 0.001), and had a longer length of mechanical ventilation (8 vs 2 d; p < 0.001). Patients who had an unplanned extubation were more likely to require cardiopulmonary resuscitation during their hospital stay (54% vs 18%; p < 0.001) and had a higher likelihood of in-hospital mortality (15% vs 7%; p = 0.001). There was a significant difference in surgical acuity as denoted by The Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery score and patients with an unplanned extubation had a higher Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery category (p = 0.019). Contributing factors associated with unplanned extubation were poor endotracheal tube tape integrity, inadequate tube securement, and/or inadequate sedation. A low rate of unplanned extubation was maintained even in the setting of increasing patient complexity and an increase in patient volume.ConclusionsA low rate of unplanned extubation is sustainable even in the setting of increased patient volume and acuity. Additionally, early identification of patients at higher risk of unplanned extubation may also contribute to decreasing the incidence of unplanned extubation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.