Knee Surg Sports Traumatol Arthrosc · Apr 2017
Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction.
- M Ettinger, T Werner-Lebeda, T Calliess, M Omar, C Becher, M Ezechieli, M Klintschar, and M Petri.
- Orthopaedic Surgery Department, Hannover Medical School (MHH), Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
- Knee Surg Sports Traumatol Arthrosc. 2017 Apr 1; 25 (4): 1241-1248.
PurposeThis cadaveric study compares the biomechanical properties of femoral graft fixation in ACL reconstruction of either quadriceps or hamstring tendon grafts with four different interference screws. The hypothesis was that quadriceps tendon grafts provide at least equal results concerning gap formation during cyclic loading and ultimate failure load compared to hamstring tendon grafts with four different interference screws.MethodsEighty porcine femora underwent interference screw fixation of human tendon grafts for ACL reconstruction. Either quadriceps (Q) or hamstring (H) tendon grafts and four different bioabsorbable interference (Wolf (W), Storz (S), Mitek (M), Arthrex (A)) screws were used, resulting in 8 groups with 10 specimens per groups (WQ, WH, SQ, SH, MQ, MH, AQ, AH). Biomechanical analysis included pretensioning the constructs with 60 N for 30 s, then cyclic loading of 500 cycles between 60 and 250 N at 1 Hz in a servohydraulic testing machine, with measurement of elongation and stiffness including video measurements. After this, ultimate failure load and failure mode analysis were performed.ResultsNo statistically significant difference could be noted between the groups regarding gap formation during cyclic loading [Cycles 21-500 (mm): WQ 3.6 ± 0.8, WH 3.9 ± 1.4, SQ 3.6 ± 0.8, SH 3.3 ± 1.5, MQ 4.3 ± 0.8, MH 4.6 ± 1.0, AQ 4.8 ± 0.8, AH 4.3 ± 1.5, n.s.], stiffness during cyclic loading [Cycles 21-500 (N/mm): WQ 72.9 ± 16.9, WH 71.6 ± 20.7, SQ 69.5 ± 23.9, SH 77.4 ± 25.1, MQ 59.6 ± 11.2, MH 48.4 ± 15.4, AQ 48.8 ± 12.7, AH 51.9 ± 22.2, n.s.], and ultimate failure load [(N): WQ 474.4 ± 88.0, WH 579.3 ± 124.2, SQ 493.9 ± 105.2, SH 576.0 ± 90.4, MQ 478.6 ± 59.0, MH 543.9 ± 119.7, AQ 480.2 ± 93.8, AH 497.8 ± 74.2, n.s.].ConclusionsQuadriceps tendon grafts yield comparable biomechanical results for femoral interference screw fixation in ACL reconstruction compared to hamstring tendon grafts. From a clinical perspective, quadriceps tendon grafts should therefore be considered as a good option in ACL reconstruction in the future.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.