Multicenter Study Observational Study
Reliability of gastric suctioning compared with ultrasound assessment of residual gastric volume: a prospective multicentre cohort study.
- L Bouvet, L Zieleskiewicz, E Loubradou, A Alain, J Morel, L Argaud, D Chassard, M Leone, B Allaouchiche, and AzuRea CAR'Echo collaborative networks.
- Department of Anaesthesia and Intensive Care, Hospices Civils de Lyon, Hôpital Femme Mère Enfant, Lyon, France.
- Anaesthesia. 2020 Mar 1; 75 (3): 323-330.
AbstractWe aimed to compare the reliability of aspiration via a nasogastric tube with ultrasound for assessment of residual gastric volume. Sixty-one adult patients who were mechanically ventilated and received continuous enteral feeding through a nasogastric tube for > 48 h were included. A first qualitative and quantitative ultrasound examination of the gastric antrum was followed by gastric suctioning, performed by an operator blinded to the result of the ultrasound examination. A second ultrasound examination was performed thereafter, followed by re-injection of the aspirated gastric contents (≤ 250 ml) into the stomach. A third ultrasound assessment was then immediately performed. If the suctioned volume was ≥ 250 ml, 250 mg erythromycin was infused over 30 min. A fourth ultrasound was performed 90 min after the third. Sixty (98%) patients had a qualitatively assessed full stomach at first ultrasound examination vs. 52 (85%) after gastric suctioning (p = 0.016). The calculated gastric volume significantly decreased after gastric suctioning, without a significant decrease in the number of patients with volume ≥ 250 ml. Four of the nine patients with calculated gastric volume ≥ 250 ml had vomiting within the last 24 h (p = 0.013). The antral cross-sectional area significantly decreased between the third and the fourth ultrasound examination (p = 0.015). Erythromycin infusion did not make a significant difference to gastric volume (n = 10). Our results demonstrate that gastric suctioning is not a reliable tool for monitoring residual gastric volume. Gastric ultrasound is a feasible and promising tool for gastric volume monitoring in clinical practice.© 2019 Association of Anaesthetists.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.