• Indian J Anaesth · Nov 2018

    A comparative evaluation of ProSeal laryngeal mask airway, I-gel and Supreme laryngeal mask airway in adult patients undergoing elective surgery: A randomised trial.

    • Anisha Singh, Anju R Bhalotra, and Raktima Anand.
    • Department of Anesthesia, Maulana Azad Medical College, New Delhi, India.
    • Indian J Anaesth. 2018 Nov 1; 62 (11): 858-864.

    Background And AimsSecond-generation supraglottic airway devices are widely used in current anaesthesia practice. This randomised study was undertaken to evaluate and compare laryngeal mask airway: ProSeal laryngeal mask airway (PLMA), Supreme laryngeal mask airway (SLMA) and I-gel.MethodsEighty-four adult patients undergoing elective surgery were randomly allocated to three groups: group P (PLMA), group I (I-gel) and group S (SLMA) of 28 patients each. Insertion times, number of insertion attempts, haemodynamic response to insertion, ease of insertion of airway device and gastric tube, oropharyngeal leak pressure (OLP) and pharyngolaryngeal morbidity were assessed. The primary outcome measure was the OLP after successful device insertion. Statistical analysis was performed using Statistical Package for the Social Sciences version 18.0 software using Chi-squared/Fisher's exact test (categorical data) and analysis of variance (continuous data) tests. P < 0.05 was considered statistically significant.ResultsThe demographic profile of patients was comparable. OLP measured after insertion, 30 minutes later and at the end of surgery differed significantly between the three groups (P < 0.001). The mean OLP was 32.64 ± 4.14 cm·H2O in group P and 29.79 ± 3.70 cm·H2O in group S. In group I, the mean OLP after insertion was 26.71 ± 3.45 cm H2O, which increased to 27.36 ± 3.22 cm H2O at 30 minutes and to 27.50 ± 3.24 cm H2O towards the end of surgery. However, these increases were not statistically significant (P = 0.641). Device insertion time was longest for group P (P = 0.001) and gastric tube insertion time was longest for group I (P = 0.001). Haemodynamic response to insertion and pharyngolaryngeal morbidity were similar with all three devices.ConclusionPLMA provides better sealing pressure but takes longer to insert. I-gel and SLMA have similar sealing pressures. I-gel insertion time is quicker.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.