• Neuromodulation · Oct 2020

    Accuracy of Template Versus Ultrasound Identification of the Reservoir Access Port of Intrathecal Drug Delivery System.

    • Camille Matthys, Myriam Jacobs, Julien Rossat, and Christophe Perruchoud.
    • Service of Anesthesiology and Pain Centre, University Hospital of Lausanne(CHUV), Switzerland.
    • Neuromodulation. 2020 Oct 1; 23 (7): 944-948.

    IntroductionPrecise localization of the center of the reservoir access port (RAP) of intrathecal pump is a crucial step to ensure a safe refill procedure. In difficult refill cases, ultrasound guidance has been reported useful. Being more expensive and time-consuming, the purpose of the study was therefore to identify situations in which sonographic localization is more accurate than the template method, in order to restrict its use to these defined conditions.Materials And MethodsThe RAP was localized using the template provided by the manufacturer and by ultrasound guidance. The distance between the two points was measured. A distance superior to 3.5 mm, corresponding to the radius of the silicone septum of the RAP, was considered a clinically significant deviation.ResultsDuring the study period, 22 patients underwent a total of 81 refill procedures. No significant correlation was found between the distance between the two points and age, height, weight, body mass index (BMI) or abdominal perimeter. The correlation was significant between distance and pump's depth. According to the ROC curve, the sensitivity of ultrasound identification of the RAP was 69.2% and the specificity 83.3% when the pump was implanted at a depth of 10 mm.DiscussionOur results are comparable to these published in the literature, pointing the usefulness of ultrasound for refill of deeply implanted pumps. Our study provides an additional element by specifying the depth from which the ultrasound seems to be superior to template.ConclusionPoor accuracy in RAP identification of intrathecal pump can lead to life-threatening complications. The results of our study suggest that the localization of recessed-RAP can be improved by ultrasound in cases of pump implanted deeper than 10 mm. For more superficially implanted devices, the template method seems to be as accurate as ultrasound.© 2019 International Neuromodulation Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.