-
Comparative Study
Tracheal intubation in microgravity: a simulation study comparing direct laryngoscopy and videolaryngoscopy†.
- Clément Starck, Séamus Thierry, Cécile Isabelle Bernard, Thierry Morineau, François Jaulin, Pascal Chapelain, and Matthieu Komorowski.
- Anesthesiology and Intensive Care Department, University Hospital of Brest, Brest, France; Space Medicine Group, European Society of Aerospace Medicine, Cologne, Germany.
- Br J Anaesth. 2020 Jul 1; 125 (1): e47-e53.
BackgroundThe risk of severe medical and surgical events during long-duration spaceflight is significant. In space, many environmental and psychological factors may make tracheal intubation more difficult than on Earth. We hypothesised that, in microgravity, tracheal intubation may be facilitated by the use of a videolaryngoscope compared with direct laryngoscopy.MethodsIn a non-randomised, controlled, cross-over simulation study, we compared intubation performance of novice operators and experts, using either a direct laryngoscope or a videolaryngoscope, in weightlessness and in normogravity. The primary outcome was the success rate of tracheal intubation. Time to intubation and the confidence score into the success of tube placement were also recorded.ResultsWhen novices attempted to intubate the trachea in microgravity, the success rate of tracheal intubation using a videolaryngoscope was significantly higher (20/25 [80%]; 95% confidence interval [CI], 64.3-95.7 vs eight/20 [40%]; 95% CI, 18.5-61.5; P=0.006), and intubation time was shorter, compared with using a direct laryngoscope. In normogravity, the success rate of tracheal intubation by experts was significantly higher than that by novices (16/20 [80%]; 95% CI, 62.5-97.5 vs seven/25 [28%]; 95% CI, 10.4-45.6; P=0.001), but in microgravity, there was no significant difference between the experts and novices (19/20 [95%]; 95% CI, 85.4-100 vs 20/25 [80%]; 95% CI, 64.3-95.7; P=0.113). Higher confidence scores were achieved with videolaryngoscopy compared with direct laryngoscopy by both experts and novices in both microgravity and normogravity.ConclusionsVideolaryngoscopy was associated with higher intubation success rate and speed, and higher confidence for correct tube placement by novice operators in microgravity, and as such may represent the best technique for advanced airway management during long-duration spaceflight.Copyright © 2019 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.