• Respiratory medicine · Nov 2015

    Electronic nose analysis of exhaled breath to diagnose ventilator-associated pneumonia.

    • R M Schnabel, M L L Boumans, A Smolinska, E E Stobberingh, R Kaufmann, P M H J Roekaerts, and D C J J Bergmans.
    • Departments of Intensive Care Medicine, Maastricht University Medical Centre, The Netherlands. Electronic address: r.schnabel@mumc.nl.
    • Respir Med. 2015 Nov 1; 109 (11): 1454-9.

    BackgroundExhaled breath analysis is an emerging technology in respiratory disease and infection. Electronic nose devices (e-nose) are small and portable with a potential for point of care application. Ventilator-associated pneumonia (VAP) is a common nosocomial infection occurring in the intensive care unit (ICU). The current best diagnostic approach is based on clinical criteria combined with bronchoalveolar lavage (BAL) and subsequent bacterial culture analysis. BAL is invasive, laborious and time consuming. Exhaled breath analysis by e-nose is non-invasive, easy to perform and could reduce diagnostic time. Aim of this study was to explore whether an e-nose can be used as a non-invasive in vivo diagnostic tool for VAP.MethodsSeventy-two patients met the clinical diagnostic criteria of VAP and underwent BAL. In thirty-three patients BAL analysis confirmed the diagnosis of VAP [BAL+(VAP+)], in thirty-nine patients the diagnosis was rejected [BAL-]. Before BAL was performed, exhaled breath was sampled from the expiratory limb of the ventilator into sterile Tedlar bags and subsequently analysed by an e-nose with metal oxide sensors (DiagNose, C-it, Zutphen, The Netherlands). From further fifty-three patients without clinical suspicion of VAP or signs of respiratory disease exhaled breath was collected to serve as a control group [control(VAP-]). The e-nose data from exhaled breath were analysed using logistic regression.ResultsThe ROC curve comparing [BAL+(VAP+)] and [control(VAP-)] patients had an area under the curve (AUC) of 0.82 (95% CI 0.73-0.9). The sensitivity was 88% with a specificity of 66%. The comparison of [BAL+(VAP+)] and [BAL-] patients revealed an AUC of 0.69; 95% CI 0.57-0.81) with a sensitivity of 76% with a specificity of 56%.ConclusionE-nose lacked sensitivity and specificity in the diagnosis of VAP in the present study for current clinical application. Further investigation into this field is warranted to explore the diagnostic possibilities of this promising new technique.Copyright © 2015 Elsevier Ltd. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.