-
- Sabino Scolletta, Antoine Herpain, Salvatore Mario Romano, Fabio Silvio Taccone, Katia Donadello, Boris Lubicz, Federico Franchi, Keitiane Michele Kaefer, Enrico Polati, Jean-Louis Vincent, and Daniel De Backer.
- Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium. sabino.scolletta@dbm.unisi.it.
- BMC Anesthesiol. 2019 Sep 4; 19 (1): 173.
BackgroundsCentral arterial pressure can be derived from analysis of the peripheral artery waveform. The aim of this study was to compare central arterial pressures measured from an intra-aortic catheter with peripheral radial arterial pressures and with central arterial pressures estimated from the peripheral pressure wave using a pressure recording analytical method (PRAM).MethodsWe studied 21 patients undergoing digital subtraction cerebral angiography under local or general anesthesia and equipped with a radial arterial catheter. A second catheter was placed in the ascending aorta for central pressure wave acquisition. Central (AO) and peripheral (RA) arterial waveforms were recorded simultaneously by PRAM for 90-180 s. During an off-line analysis, AO pressures were reconstructed (AOrec) from the RA trace using a mathematical model obtained by multi-linear regression analysis. The AOrec values obtained by PRAM were compared with the true central pressure value obtained from the catheter placed in the ascending aorta.ResultsSystolic, diastolic and mean pressures ranged from 79 to 180 mmHg, 47 to 102 mmHg, and 58 to 128 mmHg, respectively, for AO, and 83 to 174 mmHg, 47 to 107 mmHg, and 60 to 129 mmHg, respectively, for RA. The correlation coefficients between AO and RA were 0.86 (p < 0.01), 0.83 (p < 0.01) and 0.86 (p < 0.01) for systolic, diastolic and mean pressures, respectively, and the mean differences - 0.3 mmHg, 2.4 mmHg and 1.5 mmHg. The correlation coefficients between AO and AOrec were 0.92 (p < 0.001), 0.87 (p < 0.001) and 0.92 (p < 0.001), for systolic, diastolic and mean pressures, respectively, and the mean differences 0.01 mmHg, 1.8 mmHg and 1.2 mmHg.ConclusionsPRAM can provide reliable estimates of central arterial pressure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.