• Eur J Trauma Emerg Surg · Aug 2021

    Outcome after treatment of distal radius fractures in the elderly using the IlluminOss® System.

    • Guido W Van Oijen, Paul A Vegt, Tjebbe Hagenaars, Van LieshoutEsther M MEMMTrauma Research Unit Department of Surgery, Erasmus MC, University Medical Center Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, The Netherlands. e.vanlieshout@erasmusmc.nl., and VerhofstadMichael H JMHJTrauma Research Unit Department of Surgery, Erasmus MC, University Medical Center Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, The Netherlands..
    • Trauma Research Unit Department of Surgery, Erasmus MC, University Medical Center Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, The Netherlands.
    • Eur J Trauma Emerg Surg. 2021 Aug 1; 47 (4): 1129-1136.

    PurposeDistal radius fractures are very common and account for approximately 17% of all fractures treated. Multiple treatment methods are available to treat these fractures, both operative and nonoperative. This study aimed at evaluating the functional and clinical outcomes after treatment of distal radius fractures with the IlluminOss® System in adult patients.MethodsA retrospective case series was performed in a single-level two-trauma center. All consecutive adult patients with a distal radius fracture, treated with the IlluminOss® System between 01 August 2012 and 15 August 2015, were included in this study. Baseline patient characteristics and clinical data were retrospectively extracted from the medical records. Radial inclination, volar/dorsal tilt, ulnar variance, and radial length were measured on the latest available standard radiographs. In addition, patients were prospectively subjected to physical examination and were asked to complete the Disabilities of the Arm, Shoulder, and Hand, Patient-Rated Wrist Evaluation, and Short Form-36 questionnaires.ResultsTwenty-six patients with 31 distal radius fractures were included. The median age at time of trauma was 77 years and 96% were females. Five patients developed a total of seven complications. Due to persisting pain one reoperation was performed, removing a small prominent part of the implant. Both patient-reported outcome scores and radiographic results were good to excellent.ConclusionsThe IlluminOss® System is a feasible option to treat distal radius fractures with seemingly good clinical and functional outcome. One out of seven complications required surgical intervention. These outcomes justify more detailed prospective research.© 2020. The Author(s).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…